4.7 Article

A simple and automated sample preparation system for subsequent halogens determination: Combustion followed by pyrohydrolysis

Journal

ANALYTICA CHIMICA ACTA
Volume 1010, Issue -, Pages 29-36

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2018.01.034

Keywords

Microwave-induced combustion; Pyrohydrolysis; Soil analysis; Halogens determination; Sample preparation

Funding

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico [309679/2014-1]
  2. Instituto Nacional de Ciencia e Tecnologia de Bioanalitica (INCTBio) [573672/2008-3]
  3. Fundacao de Amparoa Pesquisa do Estado do Rio Grande do Sul (FAPERGS) [16/2551-0000222-3]

Ask authors/readers for more resources

A simple and automated system based on combustion followed by a pyrohydrolysis reaction was proposed for further halogens determination. This system was applied for digestion of soils containing high (90%) and also low (10%) organic matter content for further halogens determination. The following parameters were evaluated: sample mass, use of microcrystalline cellulose and heating time. For analytes absorption, a diluted alkaline solution (6 mL of 25 mmol L-1 NH4OH) was used in all experiments. Up to 400 mg of soil with high organic matter content and 100 mg of soil with low organic matter content (mixed with 400mg of cellulose) could be completely digested using the proposed system. Quantitative results for all halogens were obtained using less than 12 min of sample preparation step (about 1.8 min for sample combustion and 10 min for pyrohydrolysis). The accuracy was evaluated using a certified reference material of coal and spiked samples. No statistical difference was observed between the certified values and results obtained by the proposed method. Additionally, the recoveries obtained using spiked samples were in the range of 98-103% with relative standard deviation values lower than 5%. The limits of quantification obtained for F, Cl, Br and I for soil with high (400 mg of soil) and low (100 mg of soil) organic matter were in the range of 0.01-2 mg g(-1) and 0.07-59 mg g(-1), respectively. The proposed system was considered as a simple and suitable alternative for soils digestion for further halogens determination by ion chromatography and inductively coupled plasma mass spectrometry techniques. (c) 2018 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available