4.4 Article

Effect of Right Ventricular Pacing on Right Ventricular Mechanics and Tricuspid Regurgitation in Patients With High-Grade Atrioventricular Block and Sinus Rhythm (from the Protection of Left Ventricular Function During Right Ventricular Pacing Study)

Journal

AMERICAN JOURNAL OF CARDIOLOGY
Volume 116, Issue 12, Pages 1875-1882

Publisher

EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
DOI: 10.1016/j.amjcard.2015.09.041

Keywords

-

Funding

  1. Medtronic

Ask authors/readers for more resources

Right ventricular (RV) pacing has been linked with lead-induced tricuspid regurgitation (TR), left ventricular (LV) dysfunction, and dyssynchrony, but the effect of pacing on RV function is unclear. We sought to investigate the effect of pacing on RV synchrony, RV function, and TR, and their association with LV function. In this substudy of the PROTECT-PACE (Protection of left ventricular function during right ventricular pacing) study of the effects of RV pacing in patients with preserved ejection fraction, 145 patients (76 RV apex and 69 non-RV apex pacing) had measurable RV parameters. We assessed tricuspid annular plane systolic excursion (TAPSE), time difference between peak TAPSE and peak mitral annular plane systolic excursion (TM-APSE-dif), global LV longitudinal strain, E/e', TR vena contracta, and TR peak gradient. Echocardiography was performed just after implantation and at 2 years. TR parameters significantly worsened after 2 years, but pacing site was not associated with changes in RV and TR parameters. No temporal change in TAPSE and TM-APSE-dif was observed overall, but worsening of TM-APSE-dif was associated with worsening TAPSE. Global longitudinal strain and E/e' both deteriorated over 2 years; these changes were significantly associated. In a multivariate regression, worsening global longitudinal strain and worsening TM-APSE-dif were significantly associated with deterioration of TAPSE. Furthermore, increased E/e' and its deterioration were associated with worsening TR vena contracta and TR peak gradient, respectively. Decreased TAPSE was also associated with deterioration of TR vena contracta. In conclusion, RV pacing appears to worsen TR, an effect which might be caused by elevated LV filling pressure due to LV dysfunction. In this study, RV pacing did not affect RV function during 2-year follow-up, but such an effect might occur if RV dyssynchrony or LV dysfunction occurred after pacing. The effect of RV pacing site on RV and TR mechanics was minor. (C) 2015 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available