4.5 Article

Outcomes of patients treated with durable polymer platinum-chromium everolimus-eluting stents: a meta-analysis of randomised trials

Journal

EUROINTERVENTION
Volume 13, Issue 8, Pages 986-+

Publisher

EUROPA EDITION
DOI: 10.4244/EIJ-D-16-00871

Keywords

clinical research; clinical trial; drug-eluting stent

Funding

  1. B. Braun Melsungen AG
  2. Biotronik
  3. Boston Scientific
  4. Irish Board for Training in Cardiovascular Medicine - MSD
  5. European Association of Percutaneous Cardiovascular Interventions (EAPCI)

Ask authors/readers for more resources

Aims: The durable polymer platinum-chromium everolimus-eluting stent (PtCr-EES) is a new-generation drug-eluting stent (DES) with a platinum-enriched metallic platform developed to improve the percutaneous treatment of patients with coronary artery disease. We sought to investigate the performance of durable polymer PtCr-EES versus other new-generation DES. Methods and results: We undertook a meta-analysis of trials in which patients receiving percutaneous coronary intervention (PCI) were randomly assigned to durable polymer PtCr-EES versus other new-generation DES (other DES). Primary efficacy and safety outcomes were target lesion revascularisation (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were myocardial infarction (MI), target vessel revascularisation (TVR), death, cardiac death and longitudinal stent deformation (LSD). A total of 11,036 patients in seven trials received a PCI with either durable polymer PtCr-EES (n=6,613) or other DES (n=4,423). This latter group comprised patients treated with biolimus-(n=325), cobalt-chromium everolimus-(n=1,940) or zotarolimus-eluting stents (n=2,158). After a median follow-up of 12 months (interquartile range 12-24), durable polymer PtCr-EES displayed a risk of TLR (odds ratio 0.98, 95% confidence interval [CI]: 0.75-1.29; p=0.90) and definite/probable ST (0.89 [0.55-1.45]; p=0.63) comparable to that of other DES. However, the durable polymer PtCr-EES was associated with a higher risk of LSD (12.05 [1.60-90.71], p=0.02) compared to other DES. There was no significant difference with regard to other secondary outcomes nor was there heterogeneity across trials. Conclusions: At one-year follow-up, the durable polymer PtCr-EES displays a performance comparable to that of other new-generation DES platforms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available