Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

Journal

ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK
Volume 27, Issue 3, Pages 218-231

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.zemedi.2016.07.002

Keywords

IOERT; radiotherapy; intraoperative imaging; dose distribution

Funding

  1. Ministerio de Economia y Competitividad, IS CIII [IPT-2012-0401-300000, TEC2013-48251-C2-1-R, DTS14/00192, PI-15/02121]
  2. Comunidad de Madrid [TOPUS-CM 52013/MIT-3024]
  3. FEDER funds
  4. National Center for Image Guided Therapy [NIH P41 EB015898]

Ask authors/readers for more resources

Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (O-arm, a cone-beam CT [CBCT] system, and BodyTom, a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (TrueBeam). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available