4.7 Article

Causes-of-death analysis of patients with cardiac resynchronization therapy: an analysis of the CeRtiTuDe cohort study

Journal

EUROPEAN HEART JOURNAL
Volume 36, Issue 41, Pages 2767-2776

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/ehv455

Keywords

Heart failure; Sudden death; Cardioverter defibrillator; Competing risk; Cardiac resynchronization

Funding

  1. French Institute of Health and Medical Research (INSERM)
  2. French Society of Cardiology
  3. Biotronik
  4. Boston Scientific
  5. Medtronic
  6. Sorin
  7. St. Jude Medical

Ask authors/readers for more resources

Aims The choice of resynchronization therapy between with (CRT-D) and without (CRT-P) a defibrillator remains a contentious issue. Cause-of-death analysis among CRT-P, compared with CRT-D, patients could help evaluate the extent to which CRT-P patients would have additionally benefited from a defibrillator in a daily clinical practice. Methods and results A total of 1705 consecutive patients implanted with a CRT (CRT-P: 535 and CRT-D: 1170) between 2008 and 2010 were enrolled in CeRtiTuDe, a multicentric prospective follow-up cohort study, with specific adjudication for causes of death at 2 years. Patients with CRT-P compared with CRT-D were older (P<0.0001), less often male (P<0.0001), more symptomatic (P = 0.0005), with less coronary artery disease (P = 0.003), wider QRS (P = 0.002), more atrial fibrillation (P<0.0001), and more co-morbidities (P = 0.04). At 2-year follow-up, the annual overall mortality rate was 83.80 [95% confidence interval (CI) 73.41-94.19] per 1000 person-years. The crude mortality rate among CRT-P patients was double compared with CRT-D (relative risk 2.01, 95% CI 1.56-2.58). In a Cox proportional hazards regression analysis, CRT-P remained associated with increased mortality (hazard ratio 1.54, 95% CI 1.07-2.21, P = 0.0209), although other potential confounders may persist. By cause-of-death analysis, 95% of the excess mortality among CRT-P subjects was related to an increase in non-sudden death. Conclusion When compared with CRT-D patients, excess mortality in CRT-P recipients was mainly due to non-sudden death. Our findings suggest that CRT-P patients, as currently selected in routine clinical practice, would not potentially benefit with the addition of a defibrillator.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available