4.3 Article

On the applicability of [18F]FBPA to predict L-BPA concentration after amino acid preloading in HuH-7 liver tumor model and the implication for liver boron neutron capture therapy

Journal

NUCLEAR MEDICINE AND BIOLOGY
Volume 44, Issue -, Pages 83-89

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.nucmedbio.2016.08.012

Keywords

BNCT; Liver malignancies; [F-18]FBPA; L-BPA; Preloading

Funding

  1. Vienna Science and Technology Fund (WWTF) [LS11-036]
  2. FRM2

Ask authors/readers for more resources

Introduction: In recent years extra-corporal application of boron neutron capture therapy (BNCT) was evaluated for liver primary tumors or liver metastases. A prerequisite for such a high-risk procedure is proof of preferential delivery and high uptake of a B-10-pharmaceutical in liver malignancies. In this work we evaluated in a preclinical tumor model if [F-18]FBPA tissue distribution measured with PET is able to predict the tissue distribution of [B-10]L-BPA. Methods: Tumor bearing mice (hepatocellular carcinoma cell line, HuH-7) were either subject of a [F-18]FBPA-PET scan with subsequent measurement of radioactivity content in extracted organs using a gamma counter or injected with [B-10]L-BPA with tissue samples analyzed by prompt gamma activation analysis (PGAA) or quantitative neutron capture radiography (QNCR).The impact of L-tyrosine, L-DOPA and L-BPA preloading on the tissue distribution of [F-18]FBPA and [B-10]L-BPA was evaluated and the pharmacokinetics of [F-18]FBPA investigated by compartment modeling. Results: We found a significant correlation between [F-18]FBPA and [B-10]L-BPA uptake in tumors and various organs as well as high accumulation levels in pancreas and kidneys as reported in previous studies. Tumor-to-liver ratios of [F-18]FBPA ranged from 1.2 to 1.5. Preloading did not increase the uptake of [F-18]FBPA or [B-10]L-BPA in any organ and compartment modeling showed no statistically significant differences in [F-18]FBPA tumor kinetics. Conclusions: [F-18]FBPA-PET predicts [B-10]L-BPA concentration after amino acid preloading in HuH-7 hepatocellular carcinoma models. Preloading had no effect on tumor uptake of [F-18]FBPA. Advances in knowledge: Despite differences in chemical structure and administered dose [F-18]FBPA and [B-10]L-BPA demonstrate an equivalent biodistribution in a preclinical tumor model. Implications for patient care: [F-18]FBPA-PET is suitable for treatment planning and dose calculations in BNCT applications for liver malignancies. However, alternative tracers with more favorable tumor-to-liver ratios should be investigated. (C) 2016 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available