4.5 Article

A simple, selective, and sensitive gas chromatography-mass spectrometry method for the analysis of five process-related impurities in atenolol bulk drug and capsule formulations

Journal

JOURNAL OF SEPARATION SCIENCE
Volume 40, Issue 15, Pages 3086-3093

Publisher

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.201700252

Keywords

beta-blockers; genotoxicity; mass spectrometry; method validation

Funding

  1. Universiti Teknologi Malaysia through Research University Grant
  2. Ministry of Higher Education Malaysia [203/PKT/6720006]
  3. Universiti Teknologi Malaysia [R.J 130000.7809.4L810]

Ask authors/readers for more resources

An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process-related impurities, viz., 4-hydroxy-L-phenylglycine,4-hydroxyphenylacetonitrile, 4-hydroxyphenylacetic acid, methyl-4-hydroxyphenylacetate, and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl) amino] propoxy} phenyl] acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX-5 column with dimensions of 50 m x 0.25 mm i.d. and 0.25 mu m film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4-hydroxy-L-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid at 0.3 ppm, and methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino] propoxy} phenyl] acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3-10 ppm for 4-hydroxy-L-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid, and 0.35-10 ppm for methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl) amino] propoxy} phenyl] acetonitrile. The correlation coefficient in each case was found =0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available