Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25 min

Journal

JOURNAL OF MICROBIOLOGICAL METHODS
Volume 132, Issue -, Pages 27-33

Publisher

ELSEVIER
DOI: 10.1016/j.mimet.2016.11.010

Keywords

Loop-mediated isothermal amplification; Most probable number; Propidium monoazide; Detection limit; Point-of-care diagnostics

Funding

  1. U.S. Environmental Protection Agency [RD83301001, EPD10016]
  2. Michigan Economic Development Corporation [06-1-P1-0557]
  3. National Institute of Environmental Health Sciences Superfund Basic Research Program [NIEHS SBRP P42ES04911]
  4. EPA [EPD10016, 673331] Funding Source: Federal RePORTER

Ask authors/readers for more resources

We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95 degrees C for 5 min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63 degrees C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting <10 CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of <10 CFU, and time to positivity of about 20 min. MPN-LAMP assays were performed for cell concentrations in the range of 105 CFU to <10 CFU. MPN values from LAMP assays confirmed that the amplifications were from <10 CFU. The method described here, applicable directly on cells at 63 degrees C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available