4.7 Article

Evaluation of aggregate and silicone-oil counts in pre-filled siliconized syringes: An orthogonal study characterising the entire subvisible size range

Journal

INTERNATIONAL JOURNAL OF PHARMACEUTICS
Volume 519, Issue 1-2, Pages 58-66

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ijpharm.2017.01.015

Keywords

Particle; Monoclonal antibody; Protein aggregation; Silicone-oil; Primary packaging; Raster image correlation spectroscopy

Funding

  1. Biotechnology and Biological Sciences Research Council (BBSRC) 'BRIC' studentship
  2. Medlmmune Ltd
  3. Biotechnology and Biological Sciences Research Council [1354326] Funding Source: researchfish

Ask authors/readers for more resources

Characterisation of particulates in therapeutic monoclonal antibody (mAb) formulations is routinely extended to the sub-visible size-range (0.1-10 mu m). Additionally, with the increased use of pre-filled syringes (PFS), particle differentiation is required between proteinaceous and non-proteinaceous particles such as silicone-oil droplets. Here, three orthogonal techniques: Raster Image Correlation Spectroscopy (RICS), Resonance Mass Measurements (RMM) and Micro-Flow Imaging (MFI), were evaluated with respect to their sub-visible particle measurement and characterisation capabilities. Particle formation in mAb PFS solutions was evaluated with increasing polysorbate-20 (PS-20) concentrations. All three techniques provided complementary but distinct information on protein aggregate and silicone-oil droplet presence. PS-20 limited the generation of mAb aggregates during agitation, while increasing the number of silicone-oil droplets (PS-20 concentration dependant). MFI and RMM revealed PS-20 lead to the formation of larger micron-sized droplets, with RICS revealing an increase in smaller sub-micron droplets. Subtle differences in data sets complicate the apparent correlation between silicone-oil sloughing and mAb aggregates' generation. RICS (though the use of a specific dye) demonstrates an improved selectivity for mAb aggregates, a broader measurement size range and smaller sample volume requirement. Thus, RICS is proposed to add value to the currently available particle measurement techniques and enable informed decisions during mAb formulation development. (C) 2017 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available