4.4 Article

Ex vivo optimisation of a heterogeneous speed of sound model of the human skull for non-invasive transcranial focused ultrasound at 1 MHz

Journal

INTERNATIONAL JOURNAL OF HYPERTHERMIA
Volume 33, Issue 6, Pages 635-645

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/02656736.2017.1295322

Keywords

High intensity focused ultrasound; ultrasound; thermal ablation; modelling

Funding

  1. Bettencourt Schueller Foundation
  2. Agence Nationale de la Recherche under the programme Future Investments [ANR-10-EQPX-15]
  3. LABEX WIFI (Laboratory of Excellence) within the French Program Investments for the Future [ANR-10-LABX-24, ANR-10-IDEX-0001-02 PSL*]

Ask authors/readers for more resources

Transcranial brain therapy has recently emerged as a non-invasive strategy for the treatment of various neurological diseases, such as essential tremor or neurogenic pain. However, treatments require millimetre-scale accuracy. The use of high frequencies (typically1MHz) decreases the ultrasonic wavelength to the millimetre scale, thereby increasing the clinical accuracy and lowering the probability of cavitation, which improves the safety of the technique compared with the use of low-frequency devices that operate at 220kHz. Nevertheless, the skull produces greater distortions of high-frequency waves relative to low-frequency waves. High-frequency waves require high-performance adaptive focusing techniques, based on modelling the wave propagation through the skull. This study sought to optimise the acoustical modelling of the skull based on computed tomography (CT) for a 1 MHz clinical brain therapy system. The best model tested in this article corresponded to a maximum speed of sound of 4000m.s(-1) in the skull bone, and it restored 86% of the optimal pressure amplitude on average in a collection of six human skulls. Compared with uncorrected focusing, the optimised non-invasive correction led to an average increase of 99% in the maximum pressure amplitude around the target and an average decrease of 48% in the distance between the peak pressure and the selected target. The attenuation through the skulls was also assessed within the bandwidth of the transducers, and it was found to vary in the range of 10 +/- 3dB at 800 kHz and 16 +/- 3dB at 1.3 MHz.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available