The combination of medical imaging with computational fluid dynamics (CFD) has enabled the study of 3-D blood flow on a patient-specific level. However, with models based on gated high-resolution data, the study of transient flows, and any model implementation into routine cardiac care, is challenging. This paper presents a novel pathway for patient-specific CFD modelling of the left ventricle (LV), using 4-D transthoracic echocardiography (TTE) as input modality. To evaluate the clinical usability, two sub-studies were performed. First, a robustness evaluation was performed, where repeated models with alternating input variables were generated for six subjects and changes in simulated output quantified. Second, a validation study was carried out, where the pathway accuracy was evaluated against pulsed-wave Doppler (100 subjects), and 2-D through-plane phase-contrast magnetic resonance imaging measurements over seven intraventricular planes (6 subjects). The robustness evaluation indicated a model deviation of <12%, with highest regional and temporal deviations at apical segments and at peak systole, respectively. The validation study showed an error of <11% (velocities <10 cm/s) for all subjects, with no significant regional or temporal differences observed. With the patient-specific pathway shown to provide robust output with high accuracy, and with the pathway dependent only on 4-D TTE, the method has a high potential to be used within future clinical studies on 3-D intraventricular flow patterns. To this, future model developments in the form of e.g., anatomically accurate LV valves may further enhance the clinical value of the simulations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available