4.5 Article

Optimization of municipal pressure pumping station layout and sewage pipe network design

Journal

ENGINEERING OPTIMIZATION
Volume 50, Issue 3, Pages 537-547

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/0305215X.2017.1327580

Keywords

Nonlinear optimization; pressurized pumping station; sewage pipe network; orthogonal test

Ask authors/readers for more resources

Accelerated urbanization places extraordinary demands on sewer networks; thus optimization research to improve the design of these systems has practical significance. In this article, a subsystem nonlinear programming model is developed to optimize pumping station layout and sewage pipe network design. The subsystem model is expanded into a large-scale complex nonlinear programming system model to find the minimum total annual cost of the pumping station and network of all pipe segments. A comparative analysis is conducted using the sewage network in Taizhou City, China, as an example. The proposed method demonstrated that significant cost savings could have been realized if the studied system had been optimized using the techniques described in this article. Therefore, the method has practical value for optimizing urban sewage projects and provides a reference for theoretical research on optimization of urban drainage pumping station layouts.