4.2 Article

Calibrating the X-ray attenuation of liquid water and correcting sample movement artefacts during in operando synchrotron X-ray radiographic imaging of polymer electrolyte membrane fuel cells

Journal

JOURNAL OF SYNCHROTRON RADIATION
Volume 23, Issue -, Pages 590-599

Publisher

INT UNION CRYSTALLOGRAPHY
DOI: 10.1107/S1600577515023899

Keywords

synchrotron radiography; sample movement; water attenuation coefficient calibration; polymer electrolyte membrane uel cells; Beer-Lambert law

Funding

  1. Thermofluids for Advanced Materials (TEAM) laboratory at the University of Toronto
  2. Natural Sciences and Engineering Research Council of Canada (NSERC)
  3. NSERC Collaborative Research and Training Experience (CREATE) Program in Distributed Generation for Remote Communities
  4. Canada Research Chairs Program
  5. Ontario Ministry of Research and Innovation Early Researcher Award

Ask authors/readers for more resources

Synchrotron X-ray radiography, due to its high temporal and spatial resolutions, provides a valuable means for understanding the in operando water transport behaviour in polymer electrolyte membrane fuel cells. The purpose of this study is to address the specific artefact of imaging sample movement, which poses a significant challenge to synchrotron-based imaging for fuel cell diagnostics. Specifically, the impact of the micrometer-scale movement of the sample was determined, and a correction methodology was developed. At a photon energy level of 20 keV, a maximum movement of 7.5 mu m resulted in a false water thickness of 0.93 cm (9% higher than the maximum amount of water that the experimental apparatus could physically contain). This artefact was corrected by image translations based on the relationship between the false water thickness value and the distance moved by the sample. The implementation of this correction method led to a significant reduction in false water thickness (to similar to 0.04 cm). Furthermore, to account for inaccuracies in pixel intensities due to the scattering effect and higher harmonics, a calibration technique was introduced for the liquid water X-ray attenuation coefficient, which was found to be 0.657 +/- 0.023 cm(-1) at 20 keV. The work presented in this paper provides valuable tools for artefact compensation and accuracy improvements for dynamic synchrotron X-ray imaging of fuel cells.