4.7 Article

Effect of different precursors on generation of reference spectra for structural molecular background correction by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry: Determination of antimony in cosmetics

Journal

TALANTA
Volume 161, Issue -, Pages 547-553

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2016.09.017

Keywords

SiO molecular spectrum; Background correction; Facial cosmetics; Antimony

Funding

  1. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [2014/12595-1]
  2. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES) [33004030072P8]
  3. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [147166/2012-8, 140934/2013-8, 303255/2013-7]
  4. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [14/12595-1] Funding Source: FAPESP

Ask authors/readers for more resources

Different precursors were evaluated for the generation of reference spectra and correction of the background caused by SiO molecules in the determination of Sb in facial cosmetics by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis. Zeolite and mica were the most effective precursors for background correction during Sb determination using the 217.581 nm and 231.147 nm lines. Full 2(3) factorial design and central composite design were used to optimize the atomizer temperature program. The optimum pyrolysis and atomization temperatures were 1500 and 2100 degrees C, respectively. A Pd(NO3)(2)/Mg(NO3)(2) mixture was employed as the chemical modifier, and calibration was performed at 217.581 nm with aqueous standards containing Sb in the range 0.5-2.25 ng, resulting in a correlation coefficient of 0.9995 and a slope of 0.1548 s ng(-1). The sample mass was in the range 0.15-0.25 mg. The accuracy of the method was determined by analysis of Montana Soil (II) certified reference material, together with addition/recovery tests. The Sb concentration found was in agreement with the certified value, at a 95% confidence level (paired t-test). Recoveries of Sb added to the samples were in the range 82-108%. The limit of quantification was 0.9 mg kg(-1) and the relative standard deviation (n=3) ranged from 0.5% to 7.1%. From thirteen analyzed samples, Sb was not detected in ten samples (blush, eye shadow and compact powder); three samples (two blush and one eye shadow) presented Sb concentration in the 9.1 - 14.5 mg kg(-1) range. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available