4.7 Article

Development and Validation of an Automatic Segmentation Algorithm for Quantification of Intracerebral Hemorrhage

Journal

STROKE
Volume 47, Issue 11, Pages 2776-2782

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/STROKEAHA.116.013779

Keywords

computed tomography; computer-assisted image analysis; intracerebral hemorrhage; machine learning; volumetric analysis

Ask authors/readers for more resources

Background and Purpose-ABC/2 is still widely accepted for volume estimations in spontaneous intracerebral hemorrhage (ICH) despite known limitations, which potentially accounts for controversial outcome-study results. The aim of this study was to establish and validate an automatic segmentation algorithm, allowing for quick and accurate quantification of ICH. Methods-A segmentation algorithm implementing first- and second-order statistics, texture, and threshold features was trained on manual segmentations with a random-forest methodology. Quantitative data of the algorithm, manual segmentations, and ABC/2 were evaluated for agreement in a study sample (n=28) and validated in an independent sample not used for algorithm training (n=30). Results-ABC/2 volumes were significantly larger compared with either manual or algorithm values, whereas no significant differences were found between the latter (P<0.0001; Friedman+Dunn's multiple comparison). Algorithm agreement with the manual reference was strong (concordance correlation coefficient 0.95 [lower 95% confidence interval 0.91]) and superior to ABC/2 (concordance correlation coefficient 0.77 [95% confidence interval 0.64]). Validation confirmed agreement in an independent sample (algorithm concordance correlation coefficient 0.99 [95% confidence interval 0.98], ABC/2 concordance correlation coefficient 0.82 [95% confidence interval 0.72]). The algorithm was closer to respective manual segmentations than ABC/2 in 52/58 cases (89.7%). Conclusions-An automatic segmentation algorithm for volumetric analysis of spontaneous ICH was developed and validated in this study. Algorithm measurements showed strong agreement with manual segmentations, whereas ABC/2 exhibited its limitations, yielding inaccurate overestimations of ICH volume. The refined, yet time-efficient, quantification of ICH by the algorithm may facilitate evaluation of clot volume as an outcome predictor and trigger for surgical interventions in the clinical setting.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available