Investigation of spatial resolution characteristics of an in vivo microcomputed tomography system

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2015.11.007

Keywords

Spatial resolution; MicroCT; MTF; Geometric magnification; X-ray; Interpolation

Funding

  1. NIH [R01 CA193378]
  2. University of Oklahoma Charles and Peggy Stephenson Cancer Center - Oklahoma Tobacco Settlement Endowment Trust
  3. Charles and Jean Smith Chair endowment fund

Ask authors/readers for more resources

The spatial resolution characteristics of an in vivo microcomputed tomography (CT) system was investigated in the in-plane (x-y), cross plane (z) and projection imaging modes. The microCT system utilized in this study employs a flat panel detector with a 127 mu m pixel pitch, a microfocus x-ray tube with a focal spot size ranging from 5-30 mu m, and accommodates three geometric magnifications (M) of 1.72, 2.54 and 5.10. The in-plane modulation transfer function (MTF) curves were measured as a function of the number of projections, geometric magnification (M), detector binning and reconstruction magnification (M-Recon). The in plane cutoff frequency (10% MTF) ranged from 2.31 lp/mm (M=1.72, 2 x 2 binning) to 12.56 lp/mm (M=5.10, 1 x 1 binning) and a bar pattern phantom validated those measurements. A slight degradation in the spatial resolution was observed when comparing the image reconstruction with 511 and 918 projections, whose effect was visible at the lower frequencies. Small value of M-Recon has little or no impact on the in-plane spatial resolution owning to a stable system. Large value of M-Recon has implications on the spatial resolution and it was evident when comparing the bar pattern images reconstructed with M-Recon = 1.25 and 2.5. The cross plane MTF curves showed that the spatial resolution increased as the slice thickness decreased. The cutoff frequencies in the projection imaging mode yielded slightly higher values as compared to the in-plane and cross plane modes at all the geometric magnifications (M). At M=5.10, the cutoff resolution of the projection and cross plane on an ultra-high contrast resolution bar chip phantom were 14.9 lp/mm and 13-13.5 lp/mm. Due to the finite focal spot size of the x-ray tube, the detector blur and the reconstruction kernel functions, the system's spatial resolution does not reach the limiting spatial resolution as defined by the Nyquist's detector criteria with an ideal point source. The geometric magnification employed in the microCTs provide a tradeoff between field of view and spatial resolution for a wide range of applications. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available