4.3 Article

Comparison of two handgrip dynamometers in older adults before elective surgery

Journal

PERIOPERATIVE MEDICINE
Volume 12, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s13741-023-00334-y

Keywords

Perioperative care; Hand strength; Muscle strength dynamometer; Aged; Frail elderly

Ask authors/readers for more resources

This study aimed to assess the correlation and concordance between the Camry digital hand grip dynamometer and the gold standard Jamar(R) hydraulic handgrip dynamometer in older adults prior to elective surgery. The results showed that there was no significant difference between the handgrip strength measurements of the two dynamometers, and they exhibited high correlation and concordance. Therefore, the Camry digital dynamometer is an affordable and valid device for measuring handgrip strength in older adults.
Background Handgrip strength is a useful measurement of muscle strength and has been proposed as a single predictor of postoperative outcomes in older adults. The aim of this study was to assess the correlation and concordance of Camry digital hand grip dynamometer (EH101) with gold standard Jamar((R)) hydraulic handgrip dynamometer in older adults previous to elective surgery. Methods A cross-sectional study was conducted on patients >= 65 years old admitted to a Chilean private hospital for elective surgery between March 2018 and February 2019. Handgrip strength was assessed 2 times with each hand prior to surgery, using both the Jamar((R)) dynamometer and the Camry digital dynamometer. The highest value of each dynamometer was used for analysis. Results We included a total of 220 patients (mean age 73.1 years old +/- 6.3). Maximal handgrip strength averaged 26.9 kg +/- 9.6 with the Camry dynamometer and 26.9 kg +/- 9.7 with the Jamar((R)) dynamometer in the right hand and 25.5 kg +/- 9.5 with the Camry dynamometer and 25.7 kg +/- 9.2 with the Jamar((R)) dynamometer with the left hand. The difference between both measures did not differ significantly from 0, with Pearson correlation index of 0.95 and Lin's concordance index of 0.95 (p < 0001). The Bland-Altman graphics show that 90% of the measures were inside the confidence limits, without systematic bias. Conclusion Camry digital dynamometer is an inexpensive and valid device to measure handgrip strength in older adults previous to elective surgery, compared to the gold standard Jamar((R)) hydraulic handgrip dynamometer.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available