Biomechanical Behavior of Carbon Fiber-Reinforced Polyetheretherketone as a Dental Implant Material in Implant-Supported Overdenture under Mandibular Trauma: A Finite Element Analysis Study
Published 2023 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Biomechanical Behavior of Carbon Fiber-Reinforced Polyetheretherketone as a Dental Implant Material in Implant-Supported Overdenture under Mandibular Trauma: A Finite Element Analysis Study
Authors
Keywords
-
Journal
Nigerian Journal of Clinical Practice
Volume 26, Issue 10, Pages 1538-1546
Publisher
Medknow
Online
2023-10-31
DOI
10.4103/njcp.njcp_239_23
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Edentulous Mandible with Four‐Splinted Interforaminal Implants Exposed to Three Different Situations of Trauma: A Preliminary Three‐Dimensional Finite Element Analysis
- (2020) Stefan Krennmair et al. DENTAL TRAUMATOLOGY
- Biomechanical comparison of the All-on-4, M-4, and V-4 techniques in an atrophic maxilla: A 3D finite element analysis
- (2020) Aysa Ayali et al. COMPUTERS IN BIOLOGY AND MEDICINE
- Enhancing Distraction Osteogenesis With CFR-PEEK Bone Pins and a 3D Printed Transfer Device to Permit Artefact-free Three-dimensional Magnetic Resonance Imaging
- (2020) Karen A. Eley et al. JOURNAL OF CRANIOFACIAL SURGERY
- FEM Analysis of Dental Implant-Abutment Interface Overdenture Components and Parametric Evaluation of Equator® and Locator® Prosthodontics Attachments
- (2019) Marco Cicciù et al. Materials
- Carbon Fiber Reinforced PEEK Composites Based on 3D-Printing Technology for Orthopedic and Dental Applications
- (2019) Xingting Han et al. Journal of Clinical Medicine
- Effect of different biocompatible implant materials on the mechanical stability of dental implants under excessive oblique load
- (2019) Khaled Bataineh et al. Clinical Implant Dentistry and Related Research
- The epidemiology of edentulous atrophic mandibular fractures in Europe
- (2019) Matteo Brucoli et al. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
- A Comparative Evaluation of Stress Distribution with Two Attachment Systems of Varying Heights in a Mandibular Implant-Supported Overdenture: A Three-Dimensional Finite Element Analysis
- (2018) Nikita Khurana et al. Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry
- PEEK materials as an alternative to titanium in dental implants: A systematic review
- (2018) Sunil Mishra et al. Clinical Implant Dentistry and Related Research
- Fatigue limits of different PEEK materials for dental implants
- (2017) Andreas Dominik Schwitalla et al. Journal of the Mechanical Behavior of Biomedical Materials
- Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
- (2017) Aysa Ayali et al. Head & Face Medicine
- Impairment of an atrophic mandible by preparation of the implant cavity: a biomechanical study
- (2016) Timm Steiner et al. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY
- Pressure behavior of different PEEK materials for dental implants
- (2016) Andreas Dominik Schwitalla et al. Journal of the Mechanical Behavior of Biomedical Materials
- Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
- (2016) Shariq Najeeb et al. Journal of Prosthodontic Research
- Influence of Alveolar Bone Loss and Different Alloys on the Biomechanical Behavior of Internal-and External-Connection Implants: A Three-Dimensional Finite Element Analysis
- (2015) Alexander Tsouknidas et al. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
- Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis
- (2015) B. Kan et al. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
- Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone
- (2015) A.D. Schwitalla et al. JOURNAL OF BIOMECHANICS
- Stability of edentulous, atrophic mandibles after insertion of different dental implants. A biomechanical study
- (2015) T. Torsiglieri et al. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
- Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: A Three-dimensional finite element study
- (2015) Svetlana Antic et al. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
- Finite-Element Analysis of a New Designed Miniplate which is Used via Intraoral Approach to the Mandible Angle Fracture
- (2015) Fatih Mehmet Coskunses et al. JOURNAL OF CRANIOFACIAL SURGERY
- Finite-Element Analysis of 3 Situations of Trauma in the Human Edentulous Mandible
- (2015) Leonardo Soriano de Mello Santos et al. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
- Effect of Implant Height Differences on Different Attachment Types and Peri-Implant Bone in Mandibular Two-Implant Overdentures: 3D Finite Element Study
- (2015) Oguz Ozan et al. Journal of Oral Implantology
- Systematic Review on Success of Narrow-Diameter Dental Implants
- (2014) Marc Klein et al. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
- Enhancement of CRF-PEEK osseointegration by plasma-sprayed hydroxyapatite: A rabbit model
- (2014) Felicia Suska et al. JOURNAL OF BIOMATERIALS APPLICATIONS
- The Influence of Implant Diameter on Its Survival: A Meta-Analysis Based on Prospective Clinical Trials
- (2013) Inmaculada Ortega-Oller et al. JOURNAL OF PERIODONTOLOGY
- Fracture of the anterior segment of the atrophic mandible related to dental implants
- (2012) M. Almasri et al. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
- Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants
- (2012) Woo-Taek Lee et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- Two implant retained overdentures––A review of the literature supporting the McGill and York consensus statements
- (2011) J.M. Thomason et al. JOURNAL OF DENTISTRY
- Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method
- (2010) João Rodrigo Sarot et al. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE
- Mandibular Fracture in Conjunction with Bicortical Penetration, Using Wide-Diameter Endosseous Dental Implants
- (2010) Won-suk Oh et al. Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry
- Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus Statement
- (2009) J. Mark Thomason et al. BRITISH DENTAL JOURNAL
- Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA
- (2008) Valentim Adelino Ricardo Barão et al. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreAdd your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload Now