4.1 Article

131I dose coefficients for a reference population using age-specific models

Journal

JOURNAL OF RADIOLOGICAL PROTECTION
Volume 43, Issue 4, Pages -

Publisher

IOP Publishing Ltd
DOI: 10.1088/1361-6498/ad04ef

Keywords

paediatric reference computational phantoms; I-131 age-specific dose coefficients; FLUKA

Ask authors/readers for more resources

Age-specific dose coefficients were estimated in this study to assess internal exposure to the general public. The results showed that the dose coefficients in the thyroid source increased with age, while S values decreased. On average, ingestion dose coefficients were 63% higher than inhalation dose coefficients. The thyroid accounted for the largest contribution to the dose coefficients.
Age-specific dose coefficients are required to assess internal exposure to the general public. This study utilizes reference age-specific biokinetic models of iodine to estimate the total number of nuclear disintegrations a(r(S),tau) occurring in source regions (r(S)) during the commitment time (tau). Age-specific S values are estimated for 35 target regions due to I-131 present in 22 r(S) using data from 10 paediatric reference computational phantoms (representing five ages for both sexes) published recently by the International Commission of Radiation Protection (ICRP). Monte Carlo transport simulations are performed in FLUKA code. The estimated & atilde;(r(S),tau) and S values are then used to compute the committed tissue equivalent dose H-T(tau) for 27 radiosensitive tissues and dose coefficients e(tau) for all five ages due to inhalation and ingestion of I-131. The derived & atilde;(r(S),tau) values in the thyroid source are observed to increase with age due to the increased retention of iodine in the thyroid. S values are found to decrease with age, mainly due to an increase in target masses. Generally, H-T(tau) values are observed to decrease with age, indicating the predominant behaviour of S values over & atilde;(r(S),tau). On average, ingestion dose coefficients are 63% higher than for inhalation in all ages. The maximum contribution to dose coefficients is from the thyroid, accounting for 96% in the case of newborns and 98%-99% for all other ages. Furthermore, the estimated e(tau) values for the reference population are observed to be lower than previously published reference values from the ICRP. The estimated S, H-T(tau) and e(tau) values can be used to improve estimations of internal doses to organs/whole body for members of the public in cases of I-131 exposure. The estimated dose coefficients can also be interpolated for other ages to accurately evaluate the doses received by the general public during I-131 therapy or during a radiological emergency.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available