Rapid Serum Tubes Reduce Transport Hemolysis and False Positive Rates for High-Sensitivity Troponin T
Published 2023 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Rapid Serum Tubes Reduce Transport Hemolysis and False Positive Rates for High-Sensitivity Troponin T
Authors
Keywords
-
Journal
CLINICA CHIMICA ACTA
Volume -, Issue -, Pages 117630
Publisher
Elsevier BV
Online
2023-11-05
DOI
10.1016/j.cca.2023.117630
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Analytic Result Variation for High-Sensitivity Cardiac Troponin: Interpretation and Consequences
- (2023) Peter A. Kavsak et al. CANADIAN JOURNAL OF CARDIOLOGY
- Retrospective analysis of intra-patient laboratory variation demonstrates that the BD Vacutainer® Barricor™ blood collection tube reduces troponin variation
- (2023) George Cembrowski et al. CLINICAL BIOCHEMISTRY
- Rapid serum clot tubes reduce haemolysis due to pneumatic tube transport
- (2022) Christopher D Koch et al. JOURNAL OF CLINICAL PATHOLOGY
- Not T too! False elevations in high-sensitivity cardiac troponin T (hs-TnT) following specimen transport
- (2022) Heather A. Paul et al. CLINICAL BIOCHEMISTRY
- The underestimated issue of non-reproducible cardiac troponin I and T results: case series and systematic review of the literature
- (2021) Julien Favresse et al. CLINICAL CHEMISTRY AND LABORATORY MEDICINE
- Lithium heparin interference in the Abbott enzymatic creatinine assay: the significance of under-filled tubes
- (2021) Maria Squires et al. ANNALS OF CLINICAL BIOCHEMISTRY
- The Hidden Cost of Hemolyzed Blood Samples in the Emergency Department
- (2021) Michael P Phelan et al. Journal of Applied Laboratory Medicine
- Impact of Switching Sample Types for High-Sensitivity Cardiac Troponin I Assays in the 0/1 Hour Algorithms
- (2020) Peter A Kavsak et al. CLINICAL CHEMISTRY
- False decrease of high-sensitivity cardiac troponin T assay in pneumatic tube system samples
- (2019) Jia Wei et al. CLINICA CHIMICA ACTA
- Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples
- (2019) Nick Neuwinger et al. CLINICAL CHEMISTRY AND LABORATORY MEDICINE
- Low volume tubes are not effective to reduce the rate of hemolyzed specimens from the emergency department
- (2013) Giuseppe Lippi et al. CLINICAL BIOCHEMISTRY
- BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer
- (2012) Christopher D. Koch et al. CLINICAL BIOCHEMISTRY
- Effectiveness of practices to reduce blood sample hemolysis in EDs: A laboratory medicine best practices systematic review and meta-analysis
- (2012) Nicholas J. Heyer et al. CLINICAL BIOCHEMISTRY
- Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories