Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver
Published 2023 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver
Authors
Keywords
-
Journal
Acta Orthopaedica
Volume 94, Issue -, Pages 550-544
Publisher
Medical Journals Sweden AB
Online
2023-11-01
DOI
10.2340/17453674.2023.24022
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- CT-based migration analysis is more precise than radiostereometric analysis for tibial implants: a phantom study on a porcine cadaver
- (2023) Lars H W Engseth et al. Acta Orthopaedica
- Precision of low-dose CT-based micromotion analysis technique for the assessment of early acetabular cup migration compared with gold standard RSA: a prospective study of 30 patients up to 1 year
- (2022) Vasileios Angelomenos et al. Acta Orthopaedica
- Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic‐based and a CT‐based volumetric model
- (2022) Emil Toft Petersen et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- CT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis
- (2022) Chun-Feng Cao et al. BMC CANCER
- Precision of CT-based micromotion analysis is comparable to radiostereometry for early migration measurements in cemented acetabular cups
- (2021) Cyrus Brodén et al. Acta Orthopaedica
- Maximum Total Point Motion of Five Points Versus All Points in Assessing Tibial Baseplate Stability
- (2021) Abigail E. Niesen et al. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME
- Low-dose CT-based implant motion analysis is a precise tool for early migration measurements of hip cups: a clinical study of 24 patients
- (2020) Cyrus Brodén et al. Acta Orthopaedica
- Effective radiation dose in radiostereometric analysis of the hip
- (2020) Ian F Blom et al. Acta Orthopaedica
- RSA-tested TKA Implants on Average Have Lower Mean 10-year Revision Rates Than Non-RSA-tested Designs
- (2020) Shaho Hasan et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design
- (2020) Bart L. Kaptein et al. Bone & Joint Journal
- Are low-dose CT scans a satisfactory substitute for stereoradiographs for migration studies? A preclinical test of low-dose CT scanning protocols and their application in a pilot patient
- (2019) Thomas Eriksson et al. ACTA RADIOLOGICA
- Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis
- (2019) S. Sporer et al. Bone & Joint Journal
- Accuracy and precision of a CT method for assessing migration in shoulder arthroplasty: an experimental study
- (2019) Cyrus Brodén et al. ACTA RADIOLOGICA
- RSA migration of total knee replacements
- (2018) Bart G Pijls et al. Acta Orthopaedica
- Model-based RSA is suitable for clinical trials on the glenoid component of reverse total shoulder arthroplasty
- (2018) Alexander Nilsskog Fraser et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- The assessment of the stability of the tibial component of a novel knee arthroplasty system using radiostereometric analysis
- (2018) T. R. Turgeon et al. Bone & Joint Journal
- Rise of the Pigs: Utilization of the Porcine Model to Study Musculoskeletal Biomechanics and Tissue Engineering During Skeletal Growth
- (2017) Stephanie G. Cone et al. TISSUE ENGINEERING PART C-METHODS
- Comparison of a novel porous titanium construct (Regenerex®) to a well proven porous coated tibial surface in cementless total knee arthroplasty — A prospective randomized RSA study with two-year follow-up
- (2016) Nikolaj S. Winther et al. KNEE
- Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study
- (2016) Cyrus Brodén et al. Biomed Research International
- Three-dimensional bone-implant movements in trochanteric hip fractures: Precision and accuracy of radiostereometric analysis in a phantom model
- (2015) Alicja J. Bojan et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Estimates of Effective Dose for CT Scans of the Lower Extremities
- (2014) Natalia Saltybaeva et al. RADIOLOGY
- Early migration of tibial components is associated with late revision
- (2012) Bart G Pijls et al. Acta Orthopaedica
- Precision and Accuracy Measurement of Radiostereometric Analysis Applied to Movement of the Sacroiliac Joint
- (2012) Thomas J. Kibsgård et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- RSA and Registries: The Quest for Phased Introduction of New Implants
- (2011) Rob G.H.H. Nelissen et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up
- (2008) C. Trozzi et al. KNEE
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreDiscover Peeref hubs
Discuss science. Find collaborators. Network.
Join a conversation