4.5 Article

Multicenter External Validation of a Nomogram for Predicting Positive Prostate-specific Membrane Antigen/Positron Emission Tomography Scan in Patients with Prostate Cancer Recurrence

Journal

EUROPEAN UROLOGY ONCOLOGY
Volume 6, Issue 1, Pages 41-48

Publisher

ELSEVIER
DOI: 10.1016/j.euo.2021.12.002

Keywords

Prostate cancer nomogram; Positron emission tomography nomogram; Prostate-specific membrane antigen; positron emission tomography; Biochemical recurrence; Prostate cancer

Ask authors/readers for more resources

This study performed external validation of a nomogram developed to predict the results of 68Ga-labeled prostate-specific membrane antigen-11 positron emission tomography/computed tomography in recurrent prostate cancer patients. The nomogram showed excellent predictive accuracy, and it was found that performing PSMA-PET when the predicted probability is >= 20% can reduce the incidence of false negative scans.
Background: A nomogram has recently been developed to predict 68Ga-labeled prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/computed tomography (PSMA-PET) results in recurrent prostate cancer (PCa) patients.Objective: To perform external validation of the original nomogram in a multicentric set-ting.Design, setting, and participants: A total of 1639 patients who underwent PSMA-PET for prostate-specific antigen (PSA) relapse after radical therapy were retrospectively included from six high-volume PET centers. The external cohort was stratified according to clinical setting categories: group 1: first-time biochemical recurrence (n = 774); group 2: PSA relapse after salvage therapy (n = 499); group-3: biochemical persistence after rad-ical prostatectomy (n = 210); and group-4: advanced-stage PCa before second-line sys-temic therapies (n = 124).Intervention: PSMA-PET in recurrent PCa.Outcome measurements and statistical analysis: PSMA-PET detection rate was assessed in the overall population and in each subgroup. A multivariable logistic regression model was produced to evaluate the predictors of a positive scan. The performance characteris-tics of the model were assessed by quantifying the predictive accuracy (PA) according to model calibration. The Youden's index was used to find the best nomogram's cutoff. Decision curve analysis (DCA) was implemented to quantify the nomogram's clinical net benefit.Results and limitations: In the external cohort, the overall detection rate was 53.8% ver-sus 51.2% in the original population. At multivariate analysis, International Society of Urological Pathology grade group, PSA, PSA doubling time, and clinical setting were inde-pendent predictors of a positive scan (all p < 0.02). The PA of the nomogram was identical to the original model (82.0%); the model showed an optimal calibration curve. The best nomogram's cutoff was 55%. In the DCA, the nomogram revealed clinical net benefit when the threshold nomogram probabilities were >= 20%. The retrospective design is a major limitation.Conclusions: The original nomogram exhibited excellent characteristics on external val-idation. The incidence of a false negative scan can be reduced if PSMA-PET is performed when the predicted probability is >= 20%.Patient summary: A nomogram has been developed to predict prostate-specific mem-brane antigen/positron emission tomography (PSMA-PET) results for recurrent prostate cancer (PCa). The nomogram represents an easy tool in the decision-making process of recurrent PCa.(c) 2021 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available