4.6 Article

Novel method for augmented reality guided endodontics: An in vitro study

Journal

JOURNAL OF DENTISTRY
Volume 132, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jdent.2023.104476

Keywords

Visual-inertial odometry; Guided endodontics; Augmented reality; Cone-beam computed tomography; Minimal invasive endodontics

Ask authors/readers for more resources

The aim of this study is to evaluate the accuracy of a novel augmented reality (AR) method for guided access cavity preparation in 3D-printed jaws. Two operators with different levels of experience performed virtually guided access cavities using an AR system on 3D-printed jaw models. The results show promising results for the use of AR as a digital guide in endodontics, but further research and development may be needed.
Objective: The aim of this study is to evaluate the accuracy in endodontics of a novel augmented reality (AR) method for guided access cavity preparation in 3D-printed jaws.Methods: Two operators with different levels of experience in endodontics performed pre-planned virtually guided access cavities through a novel markerless AR system on three sets of 3D-printed jaw models (Objet Connex 350, Stratasys) mounted on a phantom. After the treatment, a post-operative high-resolution CBCT scan (NewTom VGI Evo, Cefla) was taken for each model and registered to the pre-operative model. All the access cavities were then digitally reconstructed by filling the cavity area using 3D medical software (3-Matic 15.0, materialize). For the anterior teeth and the premolars, the deviation at the coronal and apical entry points as well as the angular deviation of the access cavity were compared to the virtual plan. For the molars, the deviation at the coronal entry point was compared to the virtual plan. Additionally, the surface area of all access cavities at the entry point was measured and compared to the virtual plan. Descriptive statistics for each parameter were performed. A 95% confidence interval was calculated.Results: A total of 90 access cavities were drilled up to a depth of 4 mm inside the tooth. The mean deviation in the frontal teeth and in the premolars at the entry point was 0.51 mm and 0.77 mm at the apical point, with a mean angular deviation of 8.5 degrees and a mean surface overlap of 57%. The mean deviation for the molars at the entry point was 0.63 mm, with a mean surface overlap of 82%. Conclusion: The use of AR as a digital guide for endodontic access cavity drilling on different teeth showed promising results and might have potential for clinical use. However, further development and research might be needed before in vivo validation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available