Inter-laboratory comparison of three earplug fit-test systems

Journal

JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE
Volume 14, Issue 4, Pages 294-305

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1080/15459624.2016.1250002

Keywords

Fit-test; hearing protection; noise reduction rating

Funding

  1. Intramural CDC HHS [CC999999] Funding Source: Medline

Ask authors/readers for more resources

The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this article. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had the highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Atten(fit-test) - Atten(ANSI)). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately +/- 2dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about +/- 2dB for FitCheck and HPD Well-Fit compared to +/- 4dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available