4.3 Article

Long-term effectiveness of advanced hybrid closed loop in children and adolescents with type 1 diabetes

Journal

PEDIATRIC DIABETES
Volume 23, Issue 8, Pages 1647-1655

Publisher

WILEY-HINDAWI
DOI: 10.1111/pedi.13440

Keywords

advanced hybrid closed loop; glycemic control; pediatrics; time in range; type 1 diabetes

Ask authors/readers for more resources

AHCL MiniMed (TM) 780G allows for rapid and sustained improvement in glycemic control in young patients with T1D, reaching recommended time in range (TIR). Teenagers showed good adherence to the technology, with optimal TIR maintained over time compared to younger children. Stricter settings were associated with better metabolic control without an increase in severe hypoglycemia occurrence.
Background Advanced hybrid closed loop (AHCL) systems are the newest tool to improve metabolic control in type 1 diabetes (T1D). Long-term glycemic control of children and adolescents with T1D switching to MiniMed (TM) 780G in a real clinical setting was evaluated. Methods Time in range (TIR) and in different glucose ranges, glycemic variability indexes, HbA1c and basal-bolus insulin distribution were evaluated in 44 subjects (mean age 14.2 +/- 4.0 years, 22 males) during manual mode period, first 14 days (A14d) and first month after auto-mode activation (A1M), first 14 days after 3 months (A3M) and 6 months (A6M) in auto-mode. Results Mean TIR at A14d was 76.3 +/- 9.6% versus 69.3 +/- 12.6% in manual mode (p < 0.001), and this improvement was maintained over 6 months. Subjects with TIR >70% and >80% in manual mode were 45% and 23%, respectively, and increased to 80% (p = 0.041) and 41% (p = 0.007) at A14d. Basal-bolus distribution changed in favor of bolus, and auto-correction boluses inversely correlated with TIR. HbA1c was 7.2 +/- 0.7% (55 mmol/mol) at baseline and significantly improved after 3 months (6.7 +/- 0.5%, 50 mmol/mol, p < 0.001) and 6 months (6.6 +/- 0.5%, 49 mmol/mol, p < 0.001). TIR was higher in individuals >13 years at all time periods (p < 0.001). Glycemic target <120 mg/dl was associated with better TIR. Conclusions AHCL MiniMed (TM) 780G allowed rapid and sustained improvement of glycemic control in young T1D patients, reaching recommended TIR. Teenagers showed good technology adherence with optimal TIR, maintained better over time compared to younger children. Stricter settings were associated with better metabolic control, without increase in severe hypoglycemia occurrence.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available