4.6 Article

Investigation of the applicability of silica-graphene hybrid materials as stationary phases for capillary liquid chromatography

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1685, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2022.463618

Keywords

Capillary liquid chromatography; Graphene oxide; Hybrid materials; Orthogonality; SiGO-C18ec

Funding

  1. Coordination for the Improvement of Higher Education Personnel (CAPES - Brazil) [001]
  2. Sao Paulo Research Foundation (FAPESP - Brazil) [2019/22724-7, 2017/02147-0, 2015/15462-5, 2014/07347-9]
  3. National Council for Scientific and Technological Development (CNPq - Brazil) [307293/2014-9, 308843/2019-3]

Ask authors/readers for more resources

Graphene and graphene-derived substances are cutting-edge materials in the field of analytical chemistry. This study evaluated the performance of SiGO-C18ec particles with different diameters in capillary LC columns and compared them with traditional C18 columns. The results showed that the 5 μm SiGO-C18ec particles exhibited the best peak capacity in 15 minutes and outperformed the C18 columns. Additionally, significant orthogonality was found between the SiGO-C18ec and C18 phases.
Graphene and graphene-derived substances are cutting-edge materials receiving increasing attention in the analytical chemistry field. Graphene oxide sheets bonded to amino silica particles functionalized with octadecyl (C18) groups and endcapped, also known as SiGO-C18ec, have been successfully employed as extraction phases and in analytical columns associated with conventional liquid chromatography (LC). In this work, SiGO-C18ec particles of 3, 5, and 10 pm nominal id were employed to pack capillary LC columns (100 mm long x 0.3 mm id), and their performance in the gradient mode was evaluated and compared. A 3 pm C18 capillary LC column (50 x 0.3 mm) was used as a reference column. Eight analytes having different polarities and topological surface areas were selected as a probe in this study: carbofuran clomazone, hexazinone, carbamazepine, citalopram, clomipramine, desipramine, and ochratoxin A. Studies about orthogonality were performed to investigate the orthogonality between the SiGO-C18ec and C18 phases. Among the SiGO-C18ec phases investigated, the column packed with 5 pm SiGO-C18ec particles presented the best peak capacity (29) in 15 min. Additionally, the performance of the columns packed with 5 pm SiGO-C18ec particles overcame the performance of the C18 columns used. Significant orthogonality was found between C18 and SiGO-C18ec packed columns; however, no significant differences were found between columns packed with SiGO-C18ec particles of different diameters. (c) 2022 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available