4.1 Article

Comparisons between artificial intelligence computer-aided detection synthesized mammograms and digital mammograms when used alone and in combination with tomosynthesis images in a virtual screening setting

Journal

JAPANESE JOURNAL OF RADIOLOGY
Volume 41, Issue 1, Pages 63-70

Publisher

SPRINGER
DOI: 10.1007/s11604-022-01327-5

Keywords

Synthetic mammography; Digital breast tomosynthesis; Digital mammography; Artificial intelligence; Breast cancer

Ask authors/readers for more resources

This study compared the performance of artificial intelligence computer-aided detection synthesized mammograms with digital mammograms in breast cancer screening. The results showed that AI CAD SM had higher accuracy and the reading time was reduced when using AI CAD SM + DBT. Therefore, AI CAD SM + DBT may be more suitable for breast cancer screening compared to DM + DBT.
Purpose To compare the reader performance of artificial intelligence computer-aided detection synthesized mammograms (AI CAD SM) with that of digital mammograms (DM) when used alone or in combination with digital breast tomosynthesis (DBT) images. Materials and methods This retrospective multireader (n = 4) study compared the reader performances in 388 cases (84 cancer, 83 benign, and 221 normal or benign cases). The overall accuracy of the breast-based assessment was determined by four radiologists using two sequential reading modes: DM followed by DM + DBT; and AI CAD SM followed by AI CAD SM + DBT. Each breast was rated by each reader using five-category ratings, where 3 or higher was considered positive. The area under the receiver-operating characteristic curve (AUC) and reading time were evaluated. Results The mean AUC values for DM, AI CAD SM, DM + DBT, and AI CAD SM + DBT were 0.863, 0.895, 0.886, and 0.902, respectively. The mean AUC of AI CAD SM was significantly higher (P < 0.0001) than that of DM. The mean AUC of AI CAD SM + DBT was higher than that of DM + DBT (P = 0.094). A significant reduction in the reading time was observed after using AI CAD SM + DBT when compared with that after using DM + DBT (P < 0.001). Conclusion AI CAD SM + DBT might prove more effective than DM + DBT in a screening setting because of its lower radiation dose, noninferiority, and shorter reading time compared to DM + DBT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available