Selective quantification of the 22-kDa isoform of human growth hormone 1 in serum and plasma by immunocapture and LC-MS/MS

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 414, Issue 20, Pages 6187-6200

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-022-04188-z

Keywords

Human growth hormone; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Biomarker; Immunocapture; Isoform

Funding

  1. ICON
  2. University Medical Center Groningen (Groningen, The Netherlands)

Ask authors/readers for more resources

The human growth hormone GH1 (22 kDa) is an important biomarker for growth disorders. A LC-MS/MS method was developed to accurately quantify GH1 and distinguish it from other isoforms. The method showed good performance in different sample types and storage conditions.
The human growth hormone GH1 (22 kDa) is a commonly measured biomarker for diagnosis and during treatment of growth disorders, but its quantification by ligand binding assays may be compromised by the occurrence of a number of isoforms. These can interfere in the assays and lead to differences in results between laboratories and potentially even in the treatment of patients. We present an LC-MS/MS method that is able to distinguish the major growth hormone isoform (GH1, 22 kDa) from other isoforms and quantify it without any interference across the clinically relevant concentration range of 0.5 to 50 ng/mL. Analysis involves purification of a 100-pt serum sample by immunocapture using an anti-GH-directed antibody, tryptic digestion, and LC-MS/MS quantification of an isoform-specific signature peptide for GH1 (22 kDa). A tryptic peptide occurring in all GH isoforms is monitored in the same 16-min analytical run as a read-out for total GH. Stable-isotope-labeled forms of these two peptides are included as internal standards. Full validation of the method according to recent guidelines, against a recombinant form of the analyte in rat plasma calibrators, demonstrated intra-assay and interassay imprecision below 6% across the calibration range for both signature peptides and recoveries between 94 and 102%. An excellent correlation was found between nominal and measured concentrations of the WHO reference standard for GH1 (22 kDa). Addition of up to 1000 ng/mL biotin or the presence of a 100-fold excess of GH binding protein did not affect the measurement. Equivalent method performance was found for analysis of GH in serum, EDTA, and heparin plasma. Analyte stability was demonstrated during all normal sample storage conditions. Comparison with the IDS-iSYS GH immunoassay showed a good correlation with the LC-MS/MS method for the isoform-specific signature peptide, but a significant positive bias was observed for the LC-MS/MS results of the peptide representing total GH. This seems to confirm the actual occurrence of other GH isoforms in serum. Finally, in serum from pregnant individuals, no quantifiable GH1 (22 kDa) was found, but relatively high concentrations of total GH.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available