4.6 Article

Quantification of PEGylated proteases with varying degree of conjugation in mixtures: An analytical protocol combining protein precipitation and capillary gel electrophoresis

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1462, Issue -, Pages 153-164

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2016.07.078

Keywords

Autocatalysis; Protease PEGylation; TCA precipitation; PEGamer quantification; High-throughput capillary gel; electrophoresis

Funding

  1. German Federal Ministry of Education and Research (BMBF)
  2. project Molecular Interaction Engineering: From Nature's Toolbox to Hybrid Technical Systems [031A095B]
  3. Tosoh Bioscience GmbH (Griesheim, Germany)

Ask authors/readers for more resources

PEGylation, i.e. the covalent attachment of chemically activated polyethylene glycol (PEG) to proteins, is a technique commonly used in biopharmaceutical industry to improve protein stability, pharmacokinetics and resistance to proteolytic degradation. Therefore, PEGylation represents a valuable strategy to reduce autocatalysis of biopharmaceutical relevant proteases during production, purification and storage. In case of non-specific random conjugation the existence of more than one accessible binding site results in conjugates which vary in position and number of attached PEG molecules. These conjugates may differ considerably in their physicochemical properties. Optimizing the reaction conditions with respect to the degree of PEGylation (number of linked PEG molecules) using high-throughput screening (HTS) technologies requires a fast and reliable analytical method which allows stopping the reaction at defined times. In this study an analytical protocol for PEGylated proteases is proposed combining preservation of sample composition by trichloroacetic acid (TCA) precipitation with high-throughput capillary gel electrophoresis (HT-CGE). The well-studied protein hen egg-white lysozyme served as a model system for validating the newly developed analytical protocol for 10 kDa mPEG-aldehyde conjugates. PEGamer species were purified by chromatographic separation for calibrating the HT-CGE system. In a case study, the serine protease Savinase which is highly sensitive to autocatalysis was randomly modified with 5 kDa and 10 kDa mPEG-aldehyde and analyzed. Using the presented TCA protocol baseline separation between PEGamer species was achieved allowing for the analysis of heterogeneous PEGamer mixtures while preventing protease autocatalysis. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available