4.4 Article

FULL-SCALE AIR EMISSIONS MONITORING AND CASTING QUALITY DEMONSTRATION OF A HYBRID HYDROLYZED COLLAGEN-ALKALI SILICATE CORE BINDER

Journal

INTERNATIONAL JOURNAL OF METALCASTING
Volume 10, Issue 2, Pages 172-189

Publisher

SPRINGER INTERNATIONAL PUBLISHING AG
DOI: 10.1007/s40962-016-0021-y

Keywords

core binders; collagen; silicates; phenolic urethane; air emissions; volatile organic compounds; metal casting; stack test

Funding

  1. Ben Franklin Technology
  2. National Science Foundation [1338710]
  3. Furness-Newburge, Inc.
  4. Div Of Industrial Innovation & Partnersh
  5. Directorate For Engineering [1338710] Funding Source: National Science Foundation

Ask authors/readers for more resources

When comparing a novel collagen and alkali silicate core binder system to a conventional phenolic urethane binder system during full-scale trials, the phenolic urethane incurred a 33.3 % higher emissions rate than did the novel binder system. This was chronicled during several hours of stack tests in a full-scale trial demonstration of 3500 novel cores at a high-volume automotive ductile iron foundry. Baseline phenolic urethane emissions were determined immediately prior to running the collagen and alkali silicate cores, when making an identical casting. Approximately 10 % of the demonstration iron castings were inspected for defects, of which none (0 %) were scrapped on account of core-related defects. Also, the novel core's shakeout was complete. These favorable results were achieved with humidity-free storage of the cores over the 10 days that the cores were made. These novel demonstration cores required somewhat longer curing time in the core-making machine, than did conventional phenolic urethane cores; and this curing rate was influenced by air flow and pressure into the core box. Also, tensile specimen tests of the collagen and alkali silicate-adhered system were higher than that of the conventional phenolic urethane system. When exposed to high humidity levels (80-95 % relative humidity) for prolonged periods of time (10 days), the collagen and alkali silicate-adhered tensile specimens degraded in terms of tensile strength and scratch hardness. These losses mostly rebounded when the tensile specimens were re-dried.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available