T-1D-weighted ihMT imaging - Part II. Investigating the long- and short-T-1D components correlation with myelin content. Comparison with R-1 and the macromolecular proton fraction

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 87, Issue 5, Pages 2329-2346

Publisher

WILEY
DOI: 10.1002/mrm.29140

Keywords

ihMT T-1D-filtering; long-T-1D components; myelin microscopy imaging; myelin specificity; short-T-1D components

Funding

  1. Association pour la Recherche sur la Sclerose en Plaques [ARSEP 2020]
  2. Agence Nationale de la Recherche [ANR-11-INBS-0006, ANR-17-CE18-0030]
  3. Institut Carnot [Carnot STAR 2020]
  4. Agence Nationale de la Recherche (ANR) [ANR-17-CE18-0030] Funding Source: Agence Nationale de la Recherche (ANR)

Ask authors/readers for more resources

This study investigated the correlation between long- and short-T-1D components and myelin content using ihMT high-pass and band-pass T-1D filters, and compared the specificity of ihMT, R-1, and MPF for myelin specific imaging. The results showed that long-T(1D) components had higher specificity to myelination compared to short components. In contrast, focusing on short-T(1D) components within a narrow range led to lower specificity. The study suggests that ihMT high-pass T-1D filters could be used as an MRI biomarker for myelin content.
Purpose To investigate the long- and short-T-1D components correlation with myelin content using inhomogeneous magnetization transfer (ihMT) high-pass and band-pass T-1D-filters and to compare ihMT, R-1, and the macromolecular proton fraction (MPF) for myelin specific imaging. Methods The 3D ihMT rapid gradient echo (ihMTRAGE) sequences with increasing switching times (Delta t) were used to derive ihMT high-pass T-1D-filters with increasing T-1D cutoff values and an ihMT band-pass T-1D-filter for components in the 100 mu s to 1 ms range. 3D spoiled gradient echo quantitative MT (SPGR-qMT) protocols were used to derive R-1 and MPF maps. The specificity of R-1, MPF, and ihMT T-1D-filters was evaluated by comparison with two histological reference techniques for myelin imaging. Results The higher contribution of long-T(1D)s as compared to the short components as Delta t got longer led to an increase in the specificity to myelination. In contrast, focusing on the signal originating from a narrow range of short-T(1D)s (< 1 ms) as isolated by the band-pass T-1D-filter led to lower specificity. In addition, the significantly lower r(2) correlation coefficient of the band-pass T-1D-filter suggests that the origin of short-T-1D components is mostly associated with non-myelin protons. Also, the important contribution of short-T(1D)s to the estimated MPF, explains its low specificity to myelination as compared to the ihMT high-pass T-1D-filters. Conclusion Long-T-1D components imaging by means of ihMT high-pass T-1D-filters is proposed as an MRI biomarker for myelin content. Future studies should enable the investigation of the sensitivity of ihMT T-1D-filters for demyelinating processes.