4.7 Article

A novel Ag/Zn bimetallic MOF as a superior sensitive biosensing platform for HCV-RNA electrochemical detection

Journal

APPLIED SURFACE SCIENCE
Volume 562, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.apsusc.2021.150202

Keywords

Electrochemical Biosensor; Glassy Carbon Electrode; HCV Nucleic Acid; Bimetallic MOF; Point-of-Care Testing

Funding

  1. National Research Centre (NRC) Foundation [E120908]

Ask authors/readers for more resources

The study developed a novel label-free electrochemical biosensor for direct detection of unamplified HCV nucleic acid based on bimetallic metal-organic framework (Ag/Zn-MOF). The biosensor showed high sensitivity, low detection limit, wide detection range, low cost, and ease of use. The bimetallic MOF exhibited excellent catalytic activity for electrochemical signal amplification.
A new label-free electrochemical biosensor was progressed for direct detection of unamplified HCV nucleic acid based on silver/zinc bimetallic metal-organic framework (Ag/Zn-MOF). Several physico-chemical techniques were used to confirm the structure and morphology. The prepared bimetallic-MOF was cast on the glassy carbon electrode (GCE) and treated with the capture probe of HCV. Then, treated with bovine serum albumin (BSA) to passivate the surface, which is ready for hybridization process once the HCV target nucleic acid was added. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used as an evidence for the successful stepwise formation of the desired biosensor. In addition, a differential pulse voltammetry (DPV) measurement was used in the presence of glucose as an electrochemical catalytic indicator. The results confirmed that the bimetallic MOF's catalytic activity stimulated glucose oxidation to gluconolactone, resulting in electrochemical signal amplification. The proposed HCV electrochemical biosensor has several advantages ease of use; low cost; high selectivity and sensitivity; a linear detection ranges from 1 fM to 100 nM; and ultra-low detection limit (0.64 fM). To date, this is the first electrochemical HCV-biosensor report based on bimetallicMOF. Consequently, this assay opens the door for designing more electrochemical biosensors regarding the electrical and catalytic activity of bimetallic-MOF.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available