4.3 Article

Improvement of analysis results from the GAGG scintillator Compton camera operated on an unmanned helicopter by selecting stable flight conditions

Journal

JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
Volume 59, Issue 1, Pages 44-54

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/00223131.2021.1948452

Keywords

Compton camera; GAGG scintillator; aerial radiation monitoring system; unmanned helicopter; cesium 137; measurement; analysis; ambient dose equivalent rate mapping; gamma-ray image reconstruction

Ask authors/readers for more resources

A Compton camera system was developed for an unmanned helicopter to characterize the distribution of radioactive materials in contaminated areas, with modifications improving the precision of hot spot detections and dose rate distributions. The results demonstrated that stable flight positions and attitude angles played a crucial role in enhancing the accuracy of the detection system.
A Compton camera system for use on an unmanned helicopter was previously developed to characterize the distribution of radioactive materials in highly contaminated areas. For this study, a Compton camera system was equipped with a small camera, laser distance meter, an attitude angle sensor, temperature sensors, and real-time monitoring software for better measurement of flight parameters and more precise detection of hot spot locations. To confirm whether the detection results were improved by the modifications, ground-level ambient dose equivalent rate distributions were derived from hovering and programmed flights over a field in Okuma, Fukushima Prefecture (Japan) and compared against readings from survey meters taken at the ground level. For one hovering flight, the correlation between the datasets was improved by selecting a period of stable flight position and attitude and restricting the deviation of the attitude angles. Between 6.0% and 7.6% improvement in the position resolution was achieved using the data from stable flight periods, even when only 1-minute data windows were used. The precision of hot spot detections and ambient dose equivalent rate distributions obtained from the Compton camera were thus improved by the aforementioned modifications to the system.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available