4.5 Article

Development and implementation of an analytical procedure for the quantification of natural and synthetic steroid hormones in whole surface waters

Publisher

ELSEVIER
DOI: 10.1016/j.jchromb.2021.122732

Keywords

Endocrine disruptors; Steroid hormones; Multi-residue method; Whole water analysis; Ultra-trace measurements; Quality of measurements

Funding

  1. ANRT (Association Nationale de la Recherche et de la Technologie) [2017/1131]

Ask authors/readers for more resources

Natural and synthetic steroid hormones are released into aquatic environments, and a sensitive multi-residue analytical strategy was developed in this study to quantify 23 steroid hormones in surface waters. The method showed satisfactory recoveries and measurement errors for most compounds, with limits of quantification achieved for the majority of target compounds. The procedure was successfully implemented in a monitoring survey of Belgian surface waters, detecting contamination by certain steroid hormones at low levels.
Natural and synthetic steroid hormones are chronically released into aquatic spheres. Whereas knowledge on their combined mode of action and the cocktail effect are needed, only few multi-class methods address the challenge of their trace quantification in surface waters. The current study describes a sensitive multi-residue analytical strategy aiming to quantify 23 steroid hormones belonging to androgens, estrogens, glucocorticoids and progestogens in whole surface waters. The procedure relies on a two-step solid-phase extraction followed by an ultra-performance liquid chromatography separation coupled to tandem mass spectrometry detection (UPLC-MS/MS). Isotope dilution was implemented when possible in order to ensure the reliability of the measurement. The procedure was optimized toward the reliable quantification of the 23 target compounds at the predicted no-effect concentrations when existing or below the ng L-1 level. Satisfactory absolute global recoveries >= 77% were obtained for almost all compounds (21 out of 23) in intermediate precision conditions. Measurement errors were comprised between -27% and +17% for the great majority of compounds (21 out of 23) with standard deviations < 20% in intermediate precision conditions. Despite signal suppression was observed in water samples, satisfactory limits of quantification were achieved, ranging from 0.035 ng L-1 for 17alpha-ethinylestradiol to 1 ng L-1 for 6beta-hydroxycortisol and 6beta-hydroxydexamethasone. Abiotic stability was demonstrated for the great majority of target compounds (22 out of 23) in reference water samples stored at 4 +/- 3 degrees C during 48 h, driving our sampling strategy. To demonstrate its fitness for purpose, the procedure was implemented in a preliminary monitoring survey of Belgian surface waters. As a result, 6 out of 23 target compounds were detected or quantified, showing a contamination by some estrogens and glucocorticoids at levels ranging from 0.1 to 0.9 ng L-1.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available