Ask authors/readers for more resources
Research focuses on enhancing sensitivity in microfluidic impedimetric sensing of micron and submicron-sized microparticles by investigating novel circular electrodes in a simulation study. Analysis of radial electrode parameters reveals significant impact on signal strength, SNR, and device sensitivity for detecting multiple bioparticles. Optimization of circular electrode geometrical parameters results in >50 dB improvement in SNR, with potential for further adaptation in nanoparticles detection.
The impedimetric sensing techniques for single cell characterization have witnessed growing interest due to their high sensitivity and widespread applications. However, adapting the method to different biological measurements in microfluidic environments under various input conditions can result in feeble signal detection leading to a drastic decrease in the sensor sensitivity. The reduced signal-to-noise ratio (SNR) hinders the signal differentiation, sensor accuracy and prohibits fully integrated point-of-care applications. Here, we address the sensitivity enhancement for microfluidic impedimetric sensing of micron and submicron-sized microparticles by exploring novel circular shape electrodes in a simulation study. The influence of radial electrode parameters on differential electrical signal is systematically analyzed in COMSOL Multiphysics using spherical particles ranging from 0.75 mu m to 5 mu m in diameter. Detailed analysis revealed the strong impact of the circular shape microelectrode geometry and the electrode gap on the signal strength, resulting SNR, and device sensitivity for multiple bioparticles detection. Specifically, > 50 dB improvement in SNR was enabled by optimizing the circular electrode geometrical parameters. Our proposed sensing modality can be adapted for nanoparticles detection by further optimizing the microfluidic device parameters.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available