4.2 Article

Data Analysis of Plastic Surgery Instrument Trays Yields Significant Cost Savings and Efficiency Gains

Journal

ANNALS OF PLASTIC SURGERY
Volume 86, Issue 6S, Pages S635-S639

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/SAP.0000000000002913

Keywords

instrument; instrumentation; instrument trays; surgical instruments; optimization; rationalization; standardization; cost savings; efficiency; quality; safety; Lean principles; continuous process improvement; healthcare value; operating room; sterile processing

Categories

Ask authors/readers for more resources

The costs of inpatient surgery have been increasing, with the operating room being a major contributor to the hospital's expenses. Many instruments are not fully utilized during surgeries, leading to significant avoidable expenses.
Purpose Inpatient surgery costs have risen 30% over the past 5 years, and the operating room accounts for up to 60% of total hospital operational expense. On average, only 13.0% to 21.9% of instruments opened for a case are used, contributing to significant avoidable reprocessing, repurchase, and labor expense. Methods A comprehensive review of 40 major instrument trays at UNC Rex Hospital was conducted using a technology service (OpFlow; Operative Flow Technologies, Raleigh, NC). Among the full scope of the project, the general plastics tray and breast reconstruction tray were evaluated for the plastic surgery service line over a 3-month period. Intraoperative data collection was performed on the exact instruments used across a standard breadth of cases. Data analytics were conducted stratifying instrument usage concordance among surgeons by tray and procedure type. After a surgeon-led review of the proposed new tray configurations, the optimized versions were implemented via a methodical change management process. Results A total of 183 plastic surgery cases were evaluated across 17 primary surgeons. On average, the instrument usage per tray was 15.8% for the general plastics tray and 23.5% for the breast reconstruction tray. After stakeholder review, 32 (45.1%) of 71 instruments were removed from the general plastics tray and 40 (36.7%) of 109 were removed from the breast reconstruction tray, resulting in a total reduction of 2652 instruments. This resulted in a decrease of 81,696 instrument sterilization cycles annually. The removal of the instruments yielded an estimated cost avoidance of US $163,800 for instrument repurchase and US $69,441 in annual resterilization savings. The instrument volume reduction is projected to save 383.5 hours of sterile processing personnel time in tray assembly annually. Conclusions An analytics-driven method applying empirical data on actual case-based instrument usage has implications for better efficiency, improved quality, and cost avoidance related to instrument repurchase and sterile processing. Given increasing cost constraints and the transition to value-based care models, leveraging a technology-based solution enables meaningful change in the sterile processing department as a source for cost reduction and quality of care improvement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings