4.5 Article

Local One-Sided Rubber Bulging Test to Measure Various Strain Paths of Metal Tube

Journal

METALS
Volume 11, Issue 5, Pages -

Publisher

MDPI
DOI: 10.3390/met11050751

Keywords

tube forming; tube bulging test; formability test; forming limit; biaxial strain; local rubber bulging; cutout shape; slit length

Ask authors/readers for more resources

The study introduced a local one-sided rubber bulging method for metal tubes to evaluate various strain paths and measure the forming limit strains under biaxial deformation. By changing the position and size of slits and cutouts, the strain paths of the metal tubes can be varied.
We proposed a local one-sided rubber bulging method of metal tubes to evaluate various strain paths at an aimed portion and measured the forming limit strains of metal tubes at the place of the occurrence of necking under biaxial deformation. Using this method, since rubber is used to give pressure from the inner side of the tube, no sealing mechanisms were necessary unlike during hydraulic pressure bulging. An opening was prepared in front of the die to locally bulge a tube at only the evaluation portion. To change the restriction conditions of the bulged region for biaxial deformation at the opening, a round or square cutout, or a slit was introduced. The test was conducted using a universal compression test machine and simple dies rather than a dedicated machine. Considering the experimental results, it was confirmed that the strain path was varied by changing the position and size of slits and cutouts. Using either a cutout or a slit, the strain path in the side of the metal tubes can be either equi-biaxial tension or simple tension, respectively. Additionally, by changing the size of the cuts or slits, the strain path can be varied.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available