Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
Published 2021 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Short‐term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation
Authors
Keywords
-
Journal
BMC Ophthalmology
Volume 21, Issue 1, Pages -
Publisher
Springer Science and Business Media LLC
Online
2021-05-06
DOI
10.1186/s12886-021-01963-x
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- One‐year visual outcomes and optical quality of femtosecond laser small incision lenticule extraction and Visian Implantable Collamer Lens (ICL V4c) implantation for high myopia
- (2020) Lingling Niu et al. ACTA OPHTHALMOLOGICA
- Determining vault size in Implantable Collamer Lenses (ICL)
- (2020) Angel Sánchez Trancón et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- Optimization of Implantable Collamer Lens Sizing based on Swept-source Anterior Segment Optical Coherence Tomography
- (2020) Tomoaki Nakamura et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c)
- (2020) Xun Chen et al. BMC Ophthalmology
- Comparison of intraoperative vs postoperative optical coherence tomography measurement of implantable collamer lens vaulting
- (2020) Julien Torbey et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer
- (2020) An-Peng Pan et al. Eye and Vision
- Determining the Potential Role of Crystalline Lens Rise in Vaulting in Posterior Chamber Phakic Collamer Lens Surgery for Correction of Myopia
- (2019) Felix Gonzalez-Lopez et al. JOURNAL OF REFRACTIVE SURGERY
- Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design
- (2019) José F. Alfonso et al. JOURNAL OF REFRACTIVE SURGERY
- Posterior Chamber Phakic Intraocular Lens Implantation for the Correction of Myopia and Myopic Astigmatism: A Retrospective 10-Year Follow-Up Study
- (2019) Tomoaki Nakamura et al. AMERICAN JOURNAL OF OPHTHALMOLOGY
- Visual outcomes of Visian ICL implantation for high myopia in patients with shallow anterior chamber depth
- (2019) Lingling Niu et al. BMC Ophthalmology
- Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography
- (2019) Akihito Igarashi et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- Implantable Collamer Lens Sizing Method Based on Swept-Source Anterior Segment Optical Coherence Tomography
- (2018) Tomoaki Nakamura et al. AMERICAN JOURNAL OF OPHTHALMOLOGY
- Incidence of Implantable Collamer Lens–induced Cataract
- (2018) Howard V. Gimbel et al. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE
- ICL versus SMILE in management of anisometropic myopic amblyopia in children
- (2018) Sherif Eissa et al. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE
- Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy
- (2018) Xi Zhang et al. BMC Ophthalmology
- Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes
- (2018) Hun Lee et al. BMC Ophthalmology
- Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study
- (2018) Felix Gonzalez-Lopez et al. Translational Vision Science & Technology
- Vault Changes Caused by Light-Induced Pupil Constriction and Accommodation in Eyes With an Implantable Collamer Lens
- (2018) Sayaka Kato et al. CORNEA
- Safety and Efficacy of a New Phakic Posterior Chamber IOL for Correction of Myopia: 3 Years of Follow-up
- (2018) Viraj Vasavada et al. JOURNAL OF REFRACTIVE SURGERY
- Implantable collamer lens surgery in patients with primary iris and/or ciliary body cysts
- (2018) Zhen Li et al. BMC Ophthalmology
- The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation
- (2017) Meng-ying Qi et al. JOURNAL OF REFRACTIVE SURGERY
- Pupil Dynamics Induced by Light Reflex After Posterior Chamber Phakic Intraocular Lens Implantation
- (2017) Kazuko Totsuka et al. JOURNAL OF REFRACTIVE SURGERY
- Augeninnendruck bei implantierten ICL mit Aquaport
- (2017) B. Repplinger et al. OPHTHALMOLOGE
- Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing
- (2017) Francesco Matarazzo et al. INTERNATIONAL OPHTHALMOLOGY
- Preoperative Biometric Parameters Predict the Vault after ICL Implantation: A Retrospective Clinical Study
- (2016) Qian-Yin Zheng et al. OPHTHALMIC RESEARCH
- Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
- (2016) Xun Chen et al. BMC Ophthalmology
- Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia
- (2016) Ivo Guber et al. JAMA Ophthalmology
- Effect of Accommodation on Vaulting and Movement of Posterior Chamber Phakic Lenses in Eyes With Implantable Collamer Lenses
- (2015) Hun Lee et al. AMERICAN JOURNAL OF OPHTHALMOLOGY
- Prevention and management of collagen copolymer phakic intraocular lens exchange: Causes and surgical techniques
- (2015) Qing-Yan Zeng et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- Optimization of an Implantable Collamer Lens Sizing Method Using High-Frequency Ultrasound Biomicroscopy
- (2012) Takashi Kojima et al. AMERICAN JOURNAL OF OPHTHALMOLOGY
- Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditions
- (2011) Are Lindland et al. ACTA OPHTHALMOLOGICA
- Evaluation of ciliary sulcus diameter using ultrasound biomicroscopy in emmetropic eyes and myopic eyes
- (2011) Julia Biermann et al. JOURNAL OF CATARACT AND REFRACTIVE SURGERY
- Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications
- (2011) Paulo Fernandes et al. JOURNAL OF REFRACTIVE SURGERY
- Correlation between Preoperative Biometry and Posterior Chamber Phakic Visian Implantable Collamer Lens Vaulting
- (2011) Dong-Hoon Lee et al. OPHTHALMOLOGY
- Ultrasound Biomicroscopy of Anterior Segment Accommodative Changes with Posterior Chamber Phakic Intraocular Lens in High Myopia
- (2011) Chixin Du et al. OPHTHALMOLOGY
- Three-year follow-up of subjective vault following myopic implantable collamer lens implantation
- (2010) José F. Alfonso et al. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- Evaluation of pupil diameter after posterior chamber phakic intraocular lens implantation
- (2009) K Kamiya et al. EYE
Discover Peeref hubs
Discuss science. Find collaborators. Network.
Join a conversationBecome a Peeref-certified reviewer
The Peeref Institute provides free reviewer training that teaches the core competencies of the academic peer review process.
Get Started