4.7 Article

Photoelectrochemical detection of human epidermal growth factor receptor 2 (HER2) based on Co3O4-ascorbic acid oxidase as multiple signal amplifier

Journal

MICROCHIMICA ACTA
Volume 188, Issue 5, Pages -

Publisher

SPRINGER WIEN
DOI: 10.1007/s00604-021-04829-7

Keywords

Photoelectrochemical detection; Hexagonal carbon nitride tubes; Human epidermal growth factor receptor 2; Magnetic nanospheres; Co3O4 nanoparticles; Ascorbic acid oxidase

Funding

  1. Hunan Provincial Science and Technology Plan Project, China [2019TP1001]
  2. Innovation-Driven Project of Central South University [2020CX002]

Ask authors/readers for more resources

A sensitive photoelectrochemical (PEC) sensor was prepared using hexagonal carbon nitride tubes (HCNT) as the photoactive material, and magnetic Fe3O4 nanospheres and Co3O4 nanoparticles were employed for signal amplification. The sensor showed a wide linear response range and a low detection limit for HER2 detection in human serum samples.
A sensitive photoelectrochemical (PEC) sensor based on hexagonal carbon nitride tubes (HCNT) as photoactive material was prepared for the detection of human epidermal growth factor receptor 2 (HER2). Magnetic Fe3O4 nanospheres (MNs) modified with anti-HER2 antibodies were employed for highly efficient capture of HER2 from serum sample, and Co3O4 nanoparticles (Co3O4 NPs) modified with ascorbic acid oxidase (AAO) as well as HER2 aptamer were used for signal amplification. When the aptamer-Co3O4-AAO probe was captured onto the electrode surface through the specific binding of the aptamer with HER2, the photocurrent intensity decreased. This was because Co3O4 NPs competed with HCNT for consumption of the excitation energy. As a consequence AAO catalyzed the oxidation of the electron donor (AA), and the aptamer-Co3O4-AAO probe increased the steric hindrance at the electrode surface, leading to significant photocurrent intensity decrease, thus realizing multiple signal amplification. Based on this signal amplification strategy, at 0 V (vs Ag/AgCl), the PEC sensor shows a wide linear response ranging from 1 pg mL(-1) to 1 ng mL(-1) with a low detection limit of 0.026 pg mL(-1) for HER2. Importantly, the prepared PEC sensor was applied for detection of HER2 in human serum samples with recoveries between 98.8 and 101%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available