4.7 Article

Efficient photochemical vapor generation of bismuth using a coiled Teflon reactor: Effect of metal sensitizers and analytical performance with flame-in-gas-shield atomizer and atomic fluorescence spectrometry

Journal

MICROCHEMICAL JOURNAL
Volume 164, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.microc.2021.105997

Keywords

Bismuth; Photochemical vapor generation; Atomic absorption spectrometry; Atomic fluorescence spectrometry; Inductively coupled plasma mass spectrometry

Funding

  1. Czech Science Foundation [19-17604Y]
  2. Czech Academy of Sciences [RVO: 68081715]
  3. Charles University [SVV260560, GAUK 1048120]

Ask authors/readers for more resources

The study achieved photochemical vapor generation of bismuth with optimal conditions determined through investigating the influence of sensitizers and reaction medium flow rate. Combining PVG with atomic fluorescence spectrometry can provide low limits of detection at a low operation cost.
Photochemical vapor generation (PVG) of bismuth was accomplished in a simple flow?injection system with a standard Hg low-pressure tube lamp and a coiled Teflon reactor. The influence of a reaction medium flow rate (irradiation time) and composition was investigated using a miniature diffusion flame atomizer and highresolution continuum source atomic absorption spectrometry. Combination of 40% (v/v) acetic acid, 1.25% (v/v) formic acid and a metal sensitizer at a flow rate of 3 mL min? 1 (irradiation time of 90 s) was found optimal. The use of various metals as sensitizers was studied to initiate and enhance PVG substantially. The evident positive effect was found for four metal cations and the enhancement effect was in the following order: Cu2+ < Cd2+ < Fe2+ ? Co2+. At 50 mg L? 1 Co2+ as the sensitizer, the overall PVG efficiency of 54 ? 2% was determined from relative comparison of sensitivities obtained with PVG and liquid nebulization coupled simultaneously to inductively coupled plasma mass spectrometry. In order to reach low limits of detection (LOD) at low operation cost, a coupling of PVG to atomic fluorescence spectrometry was tested and conditions of atomization in two flame atomizers were optimized. A blank-limited LOD of 12 ng L? 1 was obtained with an advanced flame-in-gas-shield atomizer, which competes with PVG coupled to inductively coupled plasma mass spectrometry (5 ng L? 1). Interferences from commonly used inorganic acids (HNO3, HCl and H2SO4) and other elements (As3+, Pb2+, Sb3+, Se4+ and Te4+) were also investigated and the accuracy was verified by analysis of water Standard Reference Material NIST 1643f.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available