4.8 Article

Wearable Strain Sensors Based on a Porous Polydimethylsiloxane Hybrid with Carbon Nanotubes and Graphene

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 13, Issue 13, Pages 15572-15583

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.0c22823

Keywords

carbon nanotubes; graphene; PDMS; porous structure; strain sensor

Funding

  1. National Natural Science Foundation of China [U1604253]
  2. Key Scientific and Technological Projects of Henan Province [202102210043]
  3. Opening Project of Key Laboratory of Materials Processing and Mold [NERC202001]
  4. Student Research Training Plan of Henan University of Science and Technology.China [2020137]

Ask authors/readers for more resources

A high-performance flexible strain sensor based on CNT-GR/PDMS nanocomposites was designed and prepared. The sensor exhibited superior gauge factors, ultralow detection limit, fast response time, good stability and durability, and frequency-/strain-dependent sensing performances. It showed wide application prospects in smart wearable devices for detecting various human motions.
High-performance flexible strain sensors are urgently needed with the rapid development of wearable intelligent electronics. Here, a bifiller of carbon nanotubes (CNTs) and graphene (GR) for filling flexible porous polydimethylsiloxane (CNT-GR/PDMS) nanocomposites is designed and prepared for strain-sensing applications. The typical microporous structure was successfully constructed using the Soxhlet extraction technique, and the connected CNTs and GR constructed a perfect three-dimensional conductive network in the porous skeleton. As a result, the stretchability and sensitivity of the CNT-GR/PDMS-based strain sensors were well regulated based on the porous structure and the typical synergistic conductive network. Based on the destruction effect of the brittle synergistic conductive network located in the outer and inner layers of the cell skeleton and the contact effect between adjacent cells in different strain ranges, the prepared CNTs-GR/PDMS-based strain sensor exhibited superior gauge factors of 182.5, 45.6, 70.2, and 186.5 in the 0-3, 3-57, 57-90, and 90-120% strain regions, respectively. In addition, this material also exhibited an ultralow detection limit (0.5% strain), a fast response time (60 ms), good stability and durability (10,000 cycles), and frequency-/strain-dependent sensing performances, making it active for the detection of various external environments. Finally, the prepared porous CNTs-GR/PDMS-based strain sensor was attached to the skin to detect various human motions, such as wrist bending, finger bending, elbow bending, and knee bending, thereby demonstrating wide application prospects in smart wearable devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available