4.7 Article

Investigation of Fire Protection Performance and Mechanical Properties of Thin-Ply Bio-Epoxy Composites

Journal

POLYMERS
Volume 13, Issue 5, Pages -

Publisher

MDPI
DOI: 10.3390/polym13050731

Keywords

bio-based epoxy laminate; thin-ply prepreg; flame retardant mat; mechanical properties; fire protection performance

Funding

  1. project of S&T bureau collaboration project R&D of Lightweight High Strength SMC materials [2017D10033]
  2. Commonweal Research Program [2019C50027]

Ask authors/readers for more resources

Hybrid composites made of bio-based thin-ply carbon fiber prepreg and flame-retardant mats were studied for their fire protection performance and mechanical properties. The addition of flame-retardant mats improved the fire protection properties by reducing ignition time and heat release rate, but led to a reduction in tensile and bending strength of the laminates.
Hybrid composites composed of bio-based thin-ply carbon fibre prepreg and flame-retardant mats (E20MI) have been produced to investigate the effects of laminate design on their fire protection performance and mechanical properties. These flame-retardant mats rely primarily on expandable graphite, mineral wool and glass fibre to generate a thermal barrier that releases incombustible gasses and protects the underlying material. A flame retardant (FR) mat is incorporated into the carbon fibre bio-based polymeric laminate and the relationship between the fire protection properties and mechanical properties is investigated. Hybrid composite laminates containing FR mats either at the exterior surfaces or embedded 2-plies deep have been tested by the limited oxygen index (LOI), vertical burning test and cone calorimetry. The addition of the surface or embedded E20MI flame retardant mats resulted in an improvement from a base line of 33.1% to 47.5% and 45.8%, respectively. All laminates passed the vertical burning test standard of FAR 25.853. Cone calorimeter data revealed an increase in the time to ignition (TTI) for the hybrid composites containing the FR mat, while the peak of heat release rate (PHRR) and total heat release (TTR) were greatly reduced. Furthermore, the maximum average rate of heat emission (MARHE) values indicated that both composites with flame retardant mats had achieved the requirements of EN 45545-2. However, the tensile strengths of laminates with surface or embedded flame-retardant mats were reduced from 1215.94 MPa to 885.92 MPa and 975.48 MPa, respectively. Similarly, the bending strength was reduced from 836.41 MPa to 767.03 MPa and 811.36 MPa, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available