Towards an effective sensing technology to monitor micro-scale interface loosening of bioelectronic implants
Published 2021 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Towards an effective sensing technology to monitor micro-scale interface loosening of bioelectronic implants
Authors
Keywords
-
Journal
Scientific Reports
Volume 11, Issue 1, Pages -
Publisher
Springer Science and Business Media LLC
Online
2021-02-11
DOI
10.1038/s41598-021-82589-3
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
- (2020) David K. Piech et al. Nature Biomedical Engineering
- Bio-compatible wireless inductive thin-film strain sensor for monitoring the growth and strain response of bone in osseointegrated prostheses
- (2019) Andrew R Burton et al. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL
- How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up
- (2019) Jonathan T Evans et al. LANCET
- How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up
- (2019) Jonathan T Evans et al. LANCET
- Novel magnetic stimulation methodology for low-current implantable medical devices
- (2019) Rodrigo Bernardo et al. MEDICAL ENGINEERING & PHYSICS
- Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants
- (2019) João Henrique Cachão et al. SENSORS
- Hip replacement
- (2018) Rory J Ferguson et al. LANCET
- Knee replacement
- (2018) Andrew J Price et al. LANCET
- A wireless closed-loop system for optogenetic peripheral neuromodulation
- (2018) Aaron D. Mickle et al. NATURE
- Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study
- (2017) Steven Leuridan et al. MEDICAL ENGINEERING & PHYSICS
- New cosurface capacitive stimulators for the development of active osseointegrative implantable devices
- (2016) Marco P. Soares dos Santos et al. Scientific Reports
- Instrumented knee joint implants: innovations and promising concepts
- (2015) João ND Torrão et al. Expert Review of Medical Devices
- Long-term implant fixation and stress-shielding in total hip replacement
- (2015) D.R. Sumner JOURNAL OF BIOMECHANICS
- Implantable microelectromechanical sensors for diagnostic monitoring and post-surgical prediction of bone fracture healing
- (2015) Kirk C. McGilvray et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Active orthopaedic implants: Towards optimality
- (2015) Marco P. Soares dos Santos et al. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS
- Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models
- (2015) Thomas Baum et al. BMC MEDICAL IMAGING
- Modeling of an Optimized Electrostimulative Hip Revision System Under Consideration of Uncertainty in the Conductivity of Bone Tissue
- (2015) Christian Schmidt et al. IEEE Journal of Biomedical and Health Informatics
- Bone and metal: An orthopaedic perspective on osseointegration of metals
- (2014) Vitali Goriainov et al. Acta Biomaterialia
- Burden of disability due to musculoskeletal (MSK) disorders
- (2014) Lyn March et al. BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY
- Electromagnetically controllable osteoclast activity
- (2014) Jung Min Hong et al. BONE
- Establishment of a Novel In Vitro Test Setup for Electric and Magnetic Stimulation of Human Osteoblasts
- (2014) P. C. Grunert et al. CELL BIOCHEMISTRY AND BIOPHYSICS
- Instrumented hip joint replacements, femoral replacements and femoral fracture stabilizers
- (2014) Marco P Soares dos Santos et al. Expert Review of Medical Devices
- Utilization rates of hip arthroplasty in OECD countries
- (2014) C. Pabinger et al. OSTEOARTHRITIS AND CARTILAGE
- Self-doped polyaniline-based interdigitated electrodes for electrical stimulation of osteoblast cell lines
- (2014) Yong Min et al. SYNTHETIC METALS
- A Review of Current Fixation Use and Registry Outcomes in Total Hip Arthroplasty: The Uncemented Paradox
- (2013) Anders Troelsen et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Instrumented hip implants: Electric supply systems
- (2013) Marco P. Soares dos Santos et al. JOURNAL OF BIOMECHANICS
- Investigation of an acoustic-mechanical method to detect implant loosening
- (2013) Cathérine Ruther et al. MEDICAL ENGINEERING & PHYSICS
- Hip arthroplasty
- (2012) Robert Pivec et al. LANCET
- High-Tech Hip Implant for Wireless Temperature Measurements In Vivo
- (2012) Georg Bergmann et al. PLoS One
- International survey of primary and revision total knee replacement
- (2011) Steven M. Kurtz et al. INTERNATIONAL ORTHOPAEDICS
- Revision rates after total joint replacement
- (2011) G. Labek et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030
- (2009) Steven M. Kurtz et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Total hip joint prosthesis for in vivo measurement of forces and moments
- (2009) Philipp Damm et al. MEDICAL ENGINEERING & PHYSICS
- Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection
- (2009) U. Marschner et al. SENSORS AND ACTUATORS A-PHYSICAL