4.6 Article

Motion-compensated noninvasive periodontal health monitoring using handheld and motor-based photoacoustic-ultrasound imaging systems

Journal

BIOMEDICAL OPTICS EXPRESS
Volume 12, Issue 3, Pages 1543-1558

Publisher

OPTICAL SOC AMER
DOI: 10.1364/BOE.417345

Keywords

-

Funding

  1. Netherlands Organisation for Health Research and Development/Nederlandse Organisatie voor Wetenschappelijk Onderzoek [116310008]
  2. National Institutes of Health [1R21AG065776, DP2 137187, R21 DE029025, R21 DE029917, S10 OD021821]
  3. National Science Foundation [DGE-1650112]

Ask authors/readers for more resources

Simultaneous visualization of teeth and periodontium using a dual-modality photoacoustic-ultrasound imaging system can aid in monitoring periodontal health. Implementation of image registration techniques helps reduce artifacts and generate accurate cross-sections, showing promise for handheld clinical periodontal imaging while minimizing operator burden and patient discomfort.
Simultaneous visualization of the teeth and periodontium is of significant clinical interest for image-based monitoring of periodontal health. We recently reported the application of a dual-modality photoacoustic-ultrasound (PA-US) imaging system for resolving periodontal anatomy and periodontal pocket depths in humans. This work utilized a linear array transducer attached to a stepper motor to generate 3D images via maximum intensity projection. This prior work also used a medical head immobilizer to reduce artifacts during volume rendering caused by motion from the subject (e.g., breathing, minor head movements). However, this solution does not completely eliminate motion artifacts while also complicating the imaging procedure and causing patient discomfort. To address this issue, we report the implementation of an image registration technique to correctly align B-mode PA-US images and generate artifact-free 2D cross-sections. Application of the deshaking technique to PA phantoms revealed 80% similarity to the ground truth when shaking was intentionally applied during stepper motor scans. Images from handheld sweeps could also be deshaken using an LED PA-US scanner. In ex vivo porcine mandibles, pigmentation of the enamel was well-estimated within 0.1 mm error. The pocket depth measured in a healthy human subject was also in good agreement with our prior study. This report demonstrates that a modality-independent registration technique can be applied to clinically relevant PA-US scans of the periodontium to reduce operator burden of skill and subject discomfort while showing potential for handheld clinical periodontal imaging. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available