Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels – An in-vitro study
Published 2021 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels – An in-vitro study
Authors
Keywords
Wear-corrosion synergism, Fretting-corrosion, Tribocorrosion, Hip implants, Modular junctions, Surface topography
Journal
Journal of the Mechanical Behavior of Biomedical Materials
Volume -, Issue -, Pages 104443
Publisher
Elsevier BV
Online
2021-03-14
DOI
10.1016/j.jmbbm.2021.104443
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers
- (2020) Maren Bechstedt et al. JOURNAL OF BIOMECHANICS
- Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty
- (2020) Jonathan A. Gustafson et al. Bone & Joint Journal
- Determination of local micromotion at the stem-neck taper junction of a bi-modular total hip prosthesis design
- (2019) Adrian Falkenberg et al. MEDICAL ENGINEERING & PHYSICS
- In Vitro Evidence for Cell‐Accelerated Corrosion Within Modular Junctions of Total Hip Replacements
- (2019) Divya Rani Bijukumar et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces
- (2019) Divya Rani Bijukumar et al. Acta Biomaterialia
- What Factors Drive Taper Corrosion?
- (2018) Robin Pourzal et al. JOURNAL OF ARTHROPLASTY
- Factors influencing taper failure of modular revision hip stems
- (2018) A. Krull et al. MEDICAL ENGINEERING & PHYSICS
- Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches
- (2018) Divya Rani Bijukumar et al. Nanomedicine-Nanotechnology Biology and Medicine
- Head Taper Corrosion Causing Head Bottoming Out and Consecutive Gross Stem Taper Failure in Total Hip Arthroplasty
- (2018) Michael M. Morlock et al. JOURNAL OF ARTHROPLASTY
- Differential toxicity of processed and non-processed states of CoCrMo degradation products generated from a hip simulator on neural cells
- (2018) Divya Rani Bijukumar et al. Nanotoxicology
- Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements
- (2017) Deborah J. Hall et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires
- (2017) Petra Močnik et al. Materials Science & Engineering C-Materials for Biological Applications
- Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
- (2016) Robin Pourzal et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation
- (2016) Ming Han Lincoln Liow et al. INTERNATIONAL ORTHOPAEDICS
- Corrosion at the Head-Neck Junction: Why Is This Happening Now?
- (2016) Joshua J. Jacobs JOURNAL OF ARTHROPLASTY
- Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation
- (2016) Dmitry Royhman et al. Journal of the Mechanical Behavior of Biomedical Materials
- Systemic cobalt toxicity from total hip arthroplasties
- (2016) M. G. Zywiel et al. Bone & Joint Journal
- Is There a Benefit to Modularity in ‘Simpler’ Femoral Revisions?
- (2015) James I. Huddleston et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- The Taper Disaster - How Could it Happen?
- (2015) Michael M. Morlock Hip International
- Fretting-corrosion in hip implant modular junctions: New experimental set-up and initial outcome
- (2015) D. Royhman et al. TRIBOLOGY INTERNATIONAL
- Utility of Modular Implants in Primary Total Hip Arthroplasty
- (2014) Daniel J. Berry JOURNAL OF ARTHROPLASTY
- Directin vivoinflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces
- (2014) Jeremy L. Gilbert et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
- An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: The influence of pH variation
- (2014) Dmitry Royhman et al. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
- Risk Factors for Early Revision After Primary Total Hip Arthroplasty in Medicare Patients
- (2013) Kevin J. Bozic et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements
- (2013) Richard B. Cook et al. JOURNAL OF ARTHROPLASTY
- Tribocorrosive behaviour of commonly used temporomandibular implants in a synovial fluid-like environment: Ti–6Al–4V and CoCrMo
- (2013) D Royhman et al. JOURNAL OF PHYSICS D-APPLIED PHYSICS
- Evaluation of taper joints with combined fatigue and crevice corrosion testing: Comparison to human explanted modular prostheses
- (2013) L. Reclaru et al. Materials Science & Engineering C-Materials for Biological Applications
- Fretting corrosion of CoCrMo and Ti6Al4V interfaces
- (2012) Viswanathan Swaminathan et al. BIOMATERIALS
- Wear-Corrosion Synergism in a CoCrMo Hip Bearing Alloy Is Influenced by Proteins
- (2012) Mathew T. Mathew et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Wear of CoCrMo alloys used in metal-on-metal hip joints: A tribocorrosion appraisal
- (2012) Stefano Mischler et al. WEAR
- Micro-abrasion–corrosion interactions of Ni–Cr/WC based coatings: Approaches to construction of tribo-corrosion maps for the abrasion–corrosion synergism
- (2011) M.M. Stack et al. ELECTROCHIMICA ACTA
- In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion
- (2011) Jeremy L. Gilbert et al. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS
- Construction of a tribocorrosion test apparatus for the hip joint: Validation, test methodology and analysis
- (2011) M.T. Mathew et al. WEAR
- Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: A comparison between two testing systems
- (2011) M.T. Mathew et al. WEAR
- Tribocorrosion behaviour of TiCxOy thin films in bio-fluids
- (2010) M.T. Mathew et al. ELECTROCHIMICA ACTA
- Micro-abrasion–corrosion of a Co–Cr/UHMWPE couple in Ringer's solution: An approach to construction of mechanism and synergism maps for application to bio-implants
- (2010) M.M. Stack et al. WEAR
- The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States
- (2009) Kevin J Bozic et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreBecome a Peeref-certified reviewer
The Peeref Institute provides free reviewer training that teaches the core competencies of the academic peer review process.
Get Started