4.6 Article

VAMS and StAGE as innovative tools for the enantioselective determination of clenbuterol in urine by LC-MS/MS

Journal

Publisher

ELSEVIER
DOI: 10.1016/j.jpba.2020.113873

Keywords

Clenbuterol; LC-MS/MS; Stop-and-go extraction (StAGE); Urine microsampling; Volumetric absorptive microsampling (VAMS)

Funding

  1. Section for the Monitoring and Control of Doping and the Protection of Health in Sporting Activities (Italian Ministry of Health), within the Research project Innovative sampling and analysis strategies for an effective doping control (call year: 2014)

Ask authors/readers for more resources

An enantioselective workflow for analyzing clenbuterol enantiomers in urine microsamples was developed and successfully validated in this study. The VAMS-StAGE-LC-MS/MS workflow showed potential for future application in anti-doping testing of clenbuterol in urine, with satisfactory results in terms of linearity, extraction yield, precision, and matrix effect.
Clenbuterol is a chiral, selective beta(2)-adrenergic agonist. It is administered as a racemic mixture for therapeutic purposes (as a bronchodilator or prospective neuroprotective agent), but also for non-therapeutic uses (athletic performance enhancement, cattle growth promotion). Aim of the present study is to develop an original, enantioselective workflow for the analysis of clenbuterol enantiomers in urine microsamples. An innovative miniaturised sampling procedure by volumetric absorptive microsampling (VAMS) and a microsample pretreatment strategy based on stop-and-go extraction (StAGE) tips were developed and coupled to an original, chiral analytical method, exploiting liquid chromatography with triple quadrupole detection (LC-MS/MS). The method was validated, with satisfactory results: good linearity (r(2) >= 0.9995) and LOQ values (0.3 ng/mL) were found over suitable concentration ranges. Extraction yield (>87 %), precision (RSD < 4.3 %) and matrix effect (85-90 %) were all within acceptable levels of confidence. After validation, the method was applied to the determination of clenbuterol in dried urine sampled by VAMS from patients taking the drug for therapeutic reasons. Analyte content ranged from 0.8 to 2.5 ng/mL per single enantiomer, with substantial retention of the original drug racemic composition. The VAMS-StAGE-LC-MS/MS workflow seems to be suitable for future application to anti-doping testing of clenbuterol in urine. (C) 2020 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available