4.7 Article

Optimization of mycoremediation treatment for the chemical oxygen demand (COD) and ammonia nitrogen (AN) removal from domestic effluent using wild-Serbian Ganoderma lucidum (WSGL)

Journal

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
Volume 28, Issue 25, Pages 32528-32544

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-021-12686-3

Keywords

Ganoderma lucidum; Wastewater treatment; Chemical oxygen demand; Ammonia-nitrogen; Optimization; Volume of pellet

Funding

  1. University Kebangsaan Malaysia [DIP-2018-016]
  2. Fundamental Research Grant Scheme under MoE [FRGS/1/2018/TK01/UKM/02/4]

Ask authors/readers for more resources

The study introduces wild-Serbian Ganoderma lucidum as a myco-alternative to conventional microbial-based wastewater treatment, showcasing its potential for high removal efficiency of COD and AN in domestic wastewater. Utilizing response surface methodology and central composite design, the research optimizes treatment design by considering temperature and mycelial pellet volume, demonstrating the effectiveness of mycoremediation in treating high organic loadings in wastewater.
The fungi-based technology, wild-Serbian Ganoderma lucidum (WSGL) as myco-alternative to existing conventional microbial-based wastewater treatment is introduced in this study as a potential alternative treatment. The mycoremediation is highly persistent for its capability to oxidatively breakdown pollutant substrates and widely researched for its medicinal properties. Utilizing the nonhazardous properties and high degradation performance of WSGL, this research aims to optimize mycoremediation treatment design for chemical oxygen demand (COD) and ammonia nitrogen (AN) removal in domestic wastewater based on proposed Model 1 (temperature and treatment time) and Model 2 (volume of pellet and treatment time) via response surface methodology (RSM). Combined process variables were temperature (C-0) (Model 1) and the volume of mycelial pellets (%) (Model 2) against treatment time (hour). Response variables for these two sets of central composite design (CCD) were the removal efficiencies of COD (%) and AN (%). The regression line fitted well with the data with R-2 values of 0.9840 (Model 1-COD), 0.9477 (Model 1-AN), 0.9988 (Model 2-COD), and 0.9990 (Model 2-AN). The lack of fit test gives the highest value of sum of squares equal to 9494.91 (Model 1-COD), 9701.68 (Model 1-AN), 23786.55 (Model 2-COD), and 13357.02 (Model 2-AN), with probability F values less than 0.05 showing significant models. The optimized temperature for Model 1 was at 25 degrees C within 24 h of treatment time with 95.1% COD and 96.3% AN removals. The optimized condition (temperature) in Model 1 was further studied in Model 2. The optimized volume of pellet for Model 2 was 0.25% in 24-h treatment time with 76.0% COD and 78.4% AN removals. Overall, the ascended sequence of high volume of pellet considered in Model 2 will slow down the degradation process. The best fit volume of pellet with maximum degradation of COD and AN is equivalent to 0.1% at 25 degrees C in 24 h. The high performance achieved demonstrates that the mycoremediation of G. lucidum is highly potential as part of the wastewater treatment system in treating domestic wastewater of high organic loadings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available