4.6 Article

Electrochemical detection of cupric ions with boron-doped diamond electrode for marine corrosion monitoring

Journal

ELECTROCHIMICA ACTA
Volume 202, Issue -, Pages 345-356

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2015.12.194

Keywords

Electrochemical sensing; Boron-doped diamond; Marine corrosion monitoring; Differential pulse voltammetry

Funding

  1. Engineering and Physical Sciences Research Council UK (EPSRC)
  2. Defence Science and Technology Laboratory (Dstl) [EP/F004362/1]
  3. EPSRC [EP/K013319/1, EP/F034296/1, EP/F004362/1] Funding Source: UKRI
  4. Engineering and Physical Sciences Research Council [EP/F034296/1, EP/F004362/1, EP/K013319/1] Funding Source: researchfish

Ask authors/readers for more resources

Corrosion induced structural failures continue to be a costly problem in many industrial situations, and the development of robust corrosion sensing systems for structural health integrity monitoring is still a demanding challenge. The applicability of corrosion monitoring of copper alloys using a boron-doped diamond electrode (BDD) has been performed based on determination of copper ions within localised corrosion microenvironments. The electrochemical behaviour of copper ions on the BDD electrode surface were first reported in details in 0.60 M NaCl aqueous solution, and the results revealed that the electrochemical processes of copper ions on the BDD electrode proceed as two successive single electron transfer steps producing two well-separated pairs of peaks in cyclic voltammograms in the chloride ion containing electrolyte solutions. Compared with perchlorate and sulphate ions, chloride ions were observed with a significant stabilization effect on copper ions via the formation of CuCl2 complex, thus having two well-separated pairs of peaks in the obtained cyclic voltammograms on the BDD electrode in the chloride ion electrolyte solution. The apparent rate constant for the redox couple of Cu2+/Cu+ in chloride ion electrolyte was determined as 0.94 x 10(-6)cm s(-1) by using quasi-steady polarisation technique, thus indicating a quasi-reversible electron transfer process of Cu2+/Cu+ redox couple. Moreover, differential pulse voltammetric results exhibited the BDD electrode is promising for corrosion monitoring of copper alloys with an excellent relationship between peak current and concentration of copper ions without significant interference from the commonly presented metal ions within the simulated marine corrosion environments. (C) 2016 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available