4.7 Article

A portable selective electrochemical sensor amplified with Fe3O4@Au-cysteamine-thymine acetic acid as conductive mediator for determination of mercuric ion

Journal

TALANTA
Volume 221, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2020.121669

Keywords

Mercuric ion; Electrochemical sensor; Fe3O4@Au nanoparticles; Cysteamine; Thymine acetic acid

Funding

  1. Young Scientist and Technologist Program (YSTP) [SCA-CO-2561-7256-TH]
  2. Thailand Graduate Institute of Science and Technology (TGIST) [TG-55-24-60-010D]
  3. Center of Excellence for Innovation in Chemistry (PERCH-CIC), Office of the Higher Education Commission, Ministry of Education (OHEC), Thailand
  4. ASEAN-European Academic University Network (ASEA-UNINET)
  5. Austrian Federal Ministry of Education, Science and Research
  6. Austrian Agency for International Mobility and Cooperation in Education, Science and Research (OeAD-GmbH)

Ask authors/readers for more resources

The sensor utilizes the specific binding of thiol group with Hg2+ and detects Hg2+ concentration by differential pulse anodic stripping voltammetry. The detection limit is 0.5 μg/L, with a wide linear range and results consistent with the standard method.
Mercury ion (Hg2+) is considered to be one of the most toxic heavy metal ions and can cause adverse effects on kidney function, the central nervous system, and the immune system. Therefore, it is important to develop a fast and simple method for sensitive and selective detection of Hg2+ in the environment. This research proposes a portable electrochemical sensor for rapid and selective detection of Hg2+. The sensor platform is designed based on thymine acetic acid anchored with cysteamine-conjugated core shell Fe3O4@Au nanoparticles (Fe3O4@Au/CA/T-COOH) immobilized on a sensing area of a screen-printed carbon electrode (SPCE) with the aid of an external magnetic field embedded in a homemade electrode holder for ease of handling. In the presence of Hg2+, the immobilized thymine combines specifically with Hg2+ and forms a thymine-Hg2+-thymine mismatch (T-Hg2+-T). The resulting amount of Hg2+ was determined by differential pulse anodic stripping voltammetry (DPASV). Under optimal conditions, the sensor exhibited two wide linearities in a range from 1 to 200 mu g L-1 and 200-2200 mu g L-1 with the reliability coefficient of determination of 0.997 and 0.999, respectively. The detection limit (LOD) and the quantification limit (LOQ) were also determined to be 0.5 mu g L-1 and 1.0 mu g L-1, respectively. The sensor was further applied for determination of Hg2+ in water samples, a certified reference material and fish samples. The results were compared with flow injection atomic spectroscopy-inductively coupled plasma-optical emission spectroscopy (FIAS-ICP-OES) systems as a reference method. Results obtained with the proposed sensor were relatively satisfactory, and they showed no significant differences at a 95% confidence level by t-test from the standard method. Therefore, considering its fast and simple advantages, this novel strategy provides a potential platform for construction of a Hg2+ electrochemical sensor.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available