4.5 Article

An effective methodology to predict infrared spectra of van der Waals complexes: A case of Ar-CO complex

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jqsrt.2020.107367

Keywords

Full-dimensional Hamiltonian; Ar-CO complex; Potential energy surfaces; Vibrational shifts

Funding

  1. National Natural Science Foundation of China [11304095, 21303254]
  2. Foundation of He'nan Educational Committee [20A140031]

Ask authors/readers for more resources

Researchers developed an effective methodology to predict the infrared spectra of van der Waals complexes, successfully applying it to the Ar-CO system. The methodology involves dividing the complex’s Hamiltonian into three parts for calculation, leading to accurate predictions of vibrational shifts and spectroscopic parameters.
In this work, we developed an effective methodology to predict infrared spectra of van der Waals complexes and successfully applied it to the prototype system of Ar-CO complex. The basic idea is to divide strictly the full-dimensional Hamiltonian of a complex into three parts, named as rigid-rotor-approximation Hamiltonian, monomer Hamiltonian, and intramolecular and intermolecular coupling Hamiltonian, respectively. Following the three parts, intermolecular potential energy surfaces (IPESs) were firstly constructed at the rigid rotor approximation for ground and vibrationally excited states of Ar-CO complex. Then, potential curves were calculated for ground and vibrationally excited states of CO monomer with the intermolecular equilibrium structural parameters fixed. Based on these PESs, the bound state calculations were performed to obtain the rovibrational levels and average structural parameters. Finally, the intermolecular and intramolecular coupling Hamiltonian was calculated using the average structural parameters obtained from the previous steps. Our predicted vibrational shifts and spectroscopic parameters for Ar-CO complex are all in good agreement with available experimental data. The vibrational shift was calculated to be -0.4384 cm(-1) for the fundamental and -0.8925 cm(-1) for the overtone bands, which reproduce experimental results with the error of 0.16% (-0.4377 cm(-1)) and 1.68% (-0.8778 cm(-1)), respectively. In brief, the advantages of this methodology are its higher accuracy for predicting infrared spectra and are less computing resources for constructing IPESs than those of the full-dimensional quantum calculations. (C) 2020 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available